VS-ASI-FC-TPE-UL-YE 1000M
1434662
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 1434662 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 438 (C-2-2017) |
| GTIN | 4046356349307 |
| Weight per Piece (excluding packing) | 222.220 g |
| Custom tariff number | 85444995 |
| Country of origin | DE (Germany) |
| Number of positions | 2 |
|---|---|
| Shielded | no |
| Type of cable | Flat-ribbon conductor |
| Cable structure | 2x 1.5 mm² |
| Duty cycle testing | suitable for drag chain |
| Length of cable | 1000 m |
| Ambient temperature (operation) | -40 °C ... 105 °C (fixed routing) |
|---|---|
| -30 °C ... 105 °C (Flexibly installed) | |
| Ambient temperature (assembly) | -30 °C ... 105 °C |
| Ambient temperature (storage/transport) | -40 °C ... 105 °C |
| Type of cable | Flat-ribbon conductor |
|---|---|
| Cable structure | 2x 1.5 mm² |
| Conductor cross section | 1.5 mm² |
| AWG signal line | 16 |
| Conductor structure signal line | 84x 0.15 mm |
| Core diameter including insulation | 2.5 mm |
| Thickness, insulation | approx. 0.5 mm |
| Wire colors | brown, blue |
| External sheath, color | lemon yellow RAL 1012 |
| Insulation resistance | ≥ 1 MΩ*km |
| Conductor resistance | ≤ 13.7 Ω/km |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 2000 V |
| Outer sheath, material | TPE |
| Material conductor insulation | TPE |
| Conductor material | Bare Cu litz wires |
| Cable weight | 64 kg/km |
| Smallest bending radius, fixed installation | ≥ 6 mm (one-time) |
| Traversing direction | horizontal, above the broadside |
| Max. bending cycles | 8000000 |
| Bending radius | 75 mm |
| Traversing rate | 4 m/s |
| Acceleration | 4 m/s² |
| Traversing direction | vertical, above the broadside |
| Max. bending cycles | 10000000 |
| Bending radius | 50 mm |
| Special properties | UL-Style 2103 |
| CSA-File LL55255-42 | |
| Flame resistance | UL 1581, Sec. 1061 (Cable Flame) |
| IEC 60332-1-2 | |
| Halogen-free | no |
| Resistance to oil | UL 1581, Sec. 480 (60 °C) |
| Other resistance | UV resistant |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -30 °C ... 105 °C (cable, flexible installation) |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |