PANASONIC ULSH201 ULSH201 LS-H201 PANASONIC Sensor head, diffuse reflective, range 300mm, cable 2m View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ULSH201 LS-H201 PANASONIC Sensor head, diffuse reflective, range 300mm, cable 2m

ULSH201

ULSH201

PANASONIC

1 unit


Automation > Digital laser - PANASONIC
LS high precision Laser Sensor

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Product NumberLS-H201
Part NumberLS-H201
ProductAmplifier-separated Type Digital Laser Sensor
DetailsSensor heads(Coaxial reflective type)
Product nameAmplifier-separated Type Digital Laser Sensor LS-500

ItemSpecifications
Product NumberLS-H201
Part NumberLS-H201
Regulatory complianceEMC Directive, RoHS Directive
Applicable amplifiersLS-501(P), LS-501(P)-C2
(Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Sensing range:H-SP mode150mm 5.906 in
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:FAST mode200mm 7.874 in
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:STD mode300mm 11.811 in
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG mode450mm 17.717 in
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG600mm 23.622 in
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:HYPR750mm 29.528 in
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Spot sizeApprox. dia. 2 mm dia. 0.079 in or less (at a distance from the sensor head of 300 mm 11.811 in)
Sensing objectOpaque, translucent, or transparent object
(Note:Make sure to confirm detection with an actual sensor before use.)
Operation indicatorOrange LED (lights up when the amplifier output is ON)
ProtectionIP40 (IEC)
Ambient temperature-10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminanceIncandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2 in X, Y, and Z direction for 2 hours each.
Shock resistance98 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Emitting element:TypeRed semiconductor laser diode
Emitting element:Peak emission wavelength660 nm 0.026 mil
Emitting element:Laser classClass 1 [IEC / EN / JIS / GB / KS / FDA]
(Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Emitting element:Max. output2mW
MaterialEnclosure: PBT
Indicator cover: Polycarbonate
Beam-emitting / receiving surfaces: Glass
Cable0.09 mm2 2-core two parallel shielded cables, 2 m 6.562 ft long
(Note:Cable cannot be extended.)
WeightNet weight: 50 g approx.
Gross weight: 80 g approx.
AccessoryMS-LS-1 (Mounting bracket): 1pc.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.