OMRON CJ2M-CPU15 CJ2M-CPU15 CJ2W9019E 392395 OMRON RS232C CPU 60K steps View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CJ2M-CPU15 CJ2W9019E 392395 OMRON RS232C CPU 60K steps

CJ2M-CPU15

CJ2W9019E

CJ2MCPU15.1

OMRON

1 Pcs.

CPU RS232C 60K steps CPU, 60K steps program, 32K words data memory, 32K words x 4 banks EM, 2560 I/O max, RS-232C serial port, USB programming port, 3 expansion racks max.

Automation > PLC CPU-module
CJ1

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Program capacity80 K stepsData memory capacity160 K wordsLogic execution time0.04 µsMax. number of expansion units40Max. number of local I/O points2560Number of built-in digital I/Os0Communication port(s)Serial RS-232C, USBProduct Height (unpacked)90 mmProduct Width (unpacked)31 mmProduct Depth (unpacked)84.5 mmProduct Weight (unpacked)130 g
ETIM for 392395 PLC's (EC000236)
Feature Name Feature Value
Performance level according to EN ISO 13849-1 (EF007399) Level a
Model (EF000010) Modular
SIL according to IEC 61508 (EF009889) None
Voltage type (supply voltage) (EF002991) AC/DC
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Type of memory (EF002996) FLASH
Radio standard UMTS (EF008525) No
Supporting protocol for EtherCAT (EF017564) No
Appendant operation agent (Ex ib) (EF004142) No
Supporting protocol for other bus systems (EF003062) No
Supporting protocol for SERCOS (EF006657) No
IO link master (EF007298) No
Rack-assembly possible (EF007018) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for IEC 60870 (EF016069) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for DNP3 (EF016068) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for IEC 61850 Ethernet (EF015389) No
Suitable for rail mounting (EF003972) Yes
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
System accessory (EF004118) No
Certified for UL hazardous location class III (EF017627) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Certified for UL hazardous location class II (EF017625) No
Certified for UL hazardous location class I (EF017622) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) No
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Additional program memory possible (EF003029) No
Supporting protocol for SafetyBUS p (EF007527) No
Appendant operation agent (Ex ia) (EF004141) No
Supporting protocol for Modbus (EF003057) No
Redundancy (EF003156) No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) No
Supporting protocol for PROFINET CBA (EF007524) No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
Certified for UL hazardous location group E (metal dusts) (EF017637) No
With optical interface (EF003028) No
With display (EF000458) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Certified for UL hazardous location group A (acetylene) (EF017632) No
Certified for UL hazardous location division 2 (EF017629) No
Certified for UL hazardous location division 1 (EF017628) No
Certified for UL hazardous location group D (propane) (EF017636) No
Supporting protocol for ASI (EF003051) No
Certified for UL hazardous location group C (ethylene) (EF017635) No
Certified for UL hazardous location group B (hydrogen) (EF017633) No
Number of HW-interfaces other (EF003027) 1
Memory size (EF002997) 676 kByte
Number of interfaces PROFINET (EF006932) 0
Number of relay outputs (EF007348) 0
Number of HW-interfaces USB (EF003025) 1
Width (EF000008) 31 mm
Number of digital inputs (EF001992) 0
Depth (EF000049) 84.5 mm
Number of HW-interfaces wireless (EF006933) 0
Number of analogue inputs (EF001994) 0
Number of HW-interfaces parallel (EF003026) 0
Number of digital outputs (EF001993) 0
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of analogue outputs (EF001995) 0
Number of HW-interfaces RS-232 (EF003021) 1
Number of HW-interfaces RS-422 (EF003022) 0
Processing time (1K, binary operation) (EF003004) 0.04 ms
Number of HW-interfaces RS-485 (EF003023) 0
Height (EF000040) 90 mm
Max. number of time switches (EF007349) 4090
Supply voltage AC 60 Hz (EF007533) 85 V
Supply voltage DC (EF007534) 24 V
Supply voltage AC 50 Hz (EF007532) 85 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.