OBO BETTERMANN OKA-W4006050 OKA-W4006050 7424424 OBO BETTERMANN Flushfloor trunking unit blank, 2400x400x60, Strip-galvanised, DIN EN 10.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

OKA-W4006050 7424424 OBO BETTERMANN Flushfloor trunking unit blank, 2400x400x60, Strip-galvanised, DIN EN 10..

OKA-W4006050

7424424

OBO BETTERMANN

2 Pcs.

Flushfloor trunking unit blank, 2400x400x60, Strip-galvanised, DIN EN 10147, Steel, St OKA-W4006050 flush pavement channel, blind 2400x400x60 Steel, St, strip galvanized, DIN EN 10346 Trunking unit, blank, height 60−110 mm. Ready-to-mount trunking unit with three blanking lids for cable laying, consisting of the trunking base (floor trough with side and floor covering contact profiles) and trunking lid. Floor trough with holding straps for self-contacting mounting of separating retainers. The scope of delivery contains 6 height-adjustable fixing brackets, 6 screed anchors and lid butt seals (3x for nominal trunking widths of 200 and 300) or height-adjustable lid butt supports: 3x for nominal trunking width 400 and 6x for nominal trunking widths 500 and 600. Trunking lid screwed on for delivery.

Automation > Underfloor installation duct flush floor open
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

CO2 Footprint (GWP) Cradle-to-Gate66,7229 kg CO2e / 1 Meter
Cover fastening, lockingno
Cover material thickness4
Covers3
Decouplableno
Dimension2400x400x60
Duct height, min.60 mm
Floor plateyes
Height-adjustment range, max.110 mm
Height-adjustment range, min.60 mm
Installation opening for on-floor tankno
Length2400 mm
MaterialSteel
Minimum screed height60
Mounting openingWithout
Mounting opening coverno
Number of compartments3 St.
Number of insertable partitions2
Number of planned flush-mount units3
Removable coveryes
Seal installation optionyes
Separating retainer fasteningLock
Suitable for expansion jointno
SurfaceStrip galvanized
Trunking height, max.110 mm
Usable cross-section12400 mm²
Width400 mm
With connection openingno
With equipotential bondingno
With overhangyes
With separating retainerno

Product Datasheet