OBO BETTERMANN OKA-W40010050DR9 OKA-W40010050DR9 7424800 OBO BETTERMANN Flushfloor trunking unit for service unit GESR9, 2400x400x100, Strip.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

OKA-W40010050DR9 7424800 OBO BETTERMANN Flushfloor trunking unit for service unit GESR9, 2400x400x100, Strip..

OKA-W40010050DR9

7424800

OBO BETTERMANN

2 Pcs.

Flushfloor trunking unit for service unit GESR9, 2400x400x100, Strip-galvanised, DIN EN 10147, Steel, St OKA-W40010050DR9 pavement flush channel, for conj. portam. GESR9 2400x400x100 Steel, St, strip galvanized, DIN EN 10346 Trunking unit for GESR9, height 100−150 mm. Ready-to-mount trunking unit with three or six device installation lids for cable laying and the installation of flush-mount units of nominal size R9, consisting of the trunking base (floor trough with side and floor covering contact profiles) and trunking lid with blank covered mounting opening. Floor trough with holding straps for self-contacting mounting of separating retainers. The scope of delivery contains 6 height-adjustable fixing brackets, 6 screed anchors and height-adjustable lid butt supports: 3x for nominal trunking width 400 and 6x for nominal trunking widths 500 and 600. Trunking lid screwed down when delivered.

Automation > Underfloor installation duct flush floor open
Other

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

CO2 Footprint (GWP) Cradle-to-Gate82,8974 kg CO2e / 1 Meter
Cover fastening, lockingno
Cover material thickness4
Covers3
Decouplableno
Dimension2400x400x100
Duct height, min.100 mm
Floor plateyes
Height-adjustment range, max.150 mm
Height-adjustment range, min.100 mm
Installation opening for on-floor tankno
Length2400 mm
MaterialSteel
Minimum screed height100
Mounting openingRound
Mounting openingFor service outlet
Mounting opening coveryes
Number of compartments3 St.
Number of insertable partitions2
Number of planned flush-mount units3
Removable coveryes
Seal installation optionyes
Suitable for expansion jointno
SurfaceStrip galvanized
Trunking height, max.150 mm
Width400 mm
With connection openingyes
With equipotential bondingno
With overhangyes
With separating retainerno

Product Datasheet