5093594 OBO BETTERMANN DESCRG. 1+2 V50-1+NPE-280 N/BOX

VG-V50-1+NPE-280

5093594

OBO BETTERMANN

1 Pcs.

DESCRG. 1+2 V50-1+NPE-280 N/BOX Combination arrester V50, 1-pole + NPE 280 V. Lightning current combination arrester, type 1+2 to DIN EN 61643-11 • For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Complete unit, pre-mounted and ready for connection in polycarbonate housing (IP66)• Lightning current arresting capacity 12.5 kA (10/350) per pole and up to 50 kA (10/350) in totalApplication: Lightning protection equipotential bonding for buildings of Class III and IV.If there is a danger of condensation forming through wind, ice, temperature or sunlight, further measures may be necessary!* Complete = upper part and base

Automation > Combined arrester for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ApprovalsVDE, UL, ÖVE
Arrester surge current (8/20 µs) [total]50 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate3,6301 kg CO2e / 1 Piece
Conductor cross-section, flexible (fine-wire), max.2 AWG
Conductor cross-section, flexible (fine-wire), max.35 mm²
Conductor cross-section, flexible (fine-wire), min.16 AWG
Conductor cross-section, flexible (fine-wire), min.1,5 mm²
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), max.2 AWG
Conductor cross-section, rigid (single-wire/multiwire), min.16 AWG
Conductor cross-section, rigid (single-wire/multiwire), min.1,5 mm²
Connection cross-section, FM terminals, max.1,5 mm²
Connection cross-section, FM terminals, max.16 AWG
Connection cross-section, FM terminals, min.21 AWG
Connection cross-section, FM terminals, min.0,5 mm²
Dimension280V
Follow current quenching capacity (eff) [N-PE]0,1 kA
Installation typePre-mounted in the housing
Integrated back-up fuseno
Lightning surge current (10/350 μs)12,5 kA
Lightning surge current (10/350)25 kA
Max. mains-side overcurrent protection160 A gL/gG
Maximum back-up fuse160 A
Maximum continuous voltage (L-N)280 V
Maximum continuous voltage (N-PE)255 V
Maximum continuous voltage AC280 V
Maximum continuous voltage DC350 V
Maximum discharge current (8/20 μs)50 kA
Maximum discharge current (8/20 μs) [L-N]50 kA
Minimum distance1,5 mm
Network formOther
Nominal discharge current (8/20 µs)30 kA
Nominal discharge current (8/20 µs) [L-N]30 kA
Nominal voltage AC (50/60 Hz)230 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole number1
Pole version1+N/PE
Protection level [L-N]≤1,3
Protection ratingIP66
Remote signallingno
Residual voltage [L-N] @ 1 kA0,7 kV
Residual voltage [L-N] @ 12.5 kA1 kV
Residual voltage [L-N] @ 5 kA0,8 kV
Response time<25 ns
Short-circuit resistance for max. mains-side overcurrent protection50 kA eff
Signalling on deviceVisual
SPD to EN 61643-11Type 1+2
SPD to IEC 61643-1Class I+II
SPD to UL 1449Type 4
TN network formyes
TN-C-S network formyes
TN-S network formyes
Torque4 Nm
TOV voltage [L-N] ‒ fail safe mode ‒ 120 min.440 V
TOV voltage [L-N] ‒ withstand mode ‒ 5 s335 V
TOV voltage [N-PE] ‒ withstand mode ‒ 200 ms1200 V
TT network formyes