LOVATO ELECTRIC PMV80NA240 PMV80NA240 LOVATO VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM, WITH OR WITHOUT NEUTRAL, MINIMUM AND MAXI.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PMV80NA240 LOVATO VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM, WITH OR WITHOUT NEUTRAL, MINIMUM AND MAXI..

PMV80NA240

10000

LOVATO ELECTRIC

1 Pcs.

VOLTAGE MONITORING RELAY FOR THREE-PHASE SYSTEM, WITH OR WITHOUT NEUTRAL, MINIMUM AND MAXIMUM AC VOLTAGE, MINIMUM AND MAXIMUM FREQUENCY. PHASE LOSS, NEUTRAL LOSS AND INCORRECT PHASE SEQUENCE, 208…240VAC 50/60HZ RELE' PROT.RETE 3F/N 208/240V MULTIFUNZ. Voltage monitoring realy for three-phase system, with or without neutral, minimum and maximum AC voltage, minimum and maximum frequency. Phase loss, neutral loss and incorrect phase sequence, 208...240VAC 50/60Hz

Automation > Voltage monitoring relay
Protection relays - LOVATO ELECTRIC

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

PMV80NA240

Voltage monitoring realy for three-phase system, with or without neutral, minimum and maximum AC voltage, minimum and maximum frequency. Phase loss, neutral loss and incorrect phase sequence, 208...240VAC 50/60Hz

Technical specifications

Type of product:
Voltage monitoring relays
Type of system:
Three-phase with/without neutral
Number of relay outputs:
2
Rated supply voltage:
Self powered
Programming mode:
Potentiometers
Order codePMV80NA240
Weight [g]200
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]095X055X075
Volume [cm³]391.875
Bar code [EAN13]8013975179840
HS Code85364900

838.53 £


ETIM for PMV80NA240 Relays (EC001438)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
Type of voltage measuring range (EF003399) AC
Voltage measuring range 1 (EF006134) 146 V
Contains function DC-voltage hysteresis (EF003398) No
Contains function DC-over voltage (EF003397) No
Contains function DC-under voltage (EF003396) No
Three-phase hysteresis possible (EF003395) Yes
Single-phase hysteresis possible (EF003394) No
Three-phase over voltage possible (EF003393) Yes
Single-phase over voltage possible (EF003392) No
Three-phase under voltage possible (EF003391) Yes
Single-phase under voltage possible (EF003390) No
With detachable clamps (EF003340) No
Number of contacts as change-over contact (EF008257) 2
Number of contacts as normally open contact (EF008256) 0
Number of contacts as normally closed contact (EF008255) 0
Min. adjustable off-delay time (EF008192) 0.1 s
Max. permitted off-delay time (EF008191) 20 s
Max. permitted delay-on energization time (EF008189) 0.5 s
Depth (EF000049) 64.9 mm
Height (EF000040) 104.7 mm
Width (EF000008) 53.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.