LAPP 1591221 1591221 A-2YF(L)2Y...ST III BD 6x2x0,8 LAPP A-2YF(L)2Y...ST III BD 6x2x0,8 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1591221 A-2YF(L)2Y...ST III BD 6x2x0,8 LAPP A-2YF(L)2Y...ST III BD 6x2x0,8

1591221

1591221

A-2YF(L)2Y...ST III BD 6x2x0,8

LAPP

100 m.

A-2YF(L)2Y...ST III BD 6x2x0,8 A-2YF(L)2Y...ST III BD Outdoor Cable

Cables > Data and communication cable
UNITRONIC low frequency

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

A-2YF(L)2Y...ST III BD - Outdoor telecommunication cable VDE 0816, longitudinal and lateral watertightness, use as directly and indirectly buried/ burial cable

Application range

  • External cables for telecommunication and data processing systems
  • Do not install cables that are meant to be placed in ducts or for direct burial in areas exposed to fire hazards

Product features

  • Outer sheath colour: black (RAL 9005)
  • UV-resistant and laterally watertight
  • Filled version (A-2YF(L)2Y...ST III BD) is addionally longitudinal watertight

Norm references / Approvals

  • In accordance with DIN VDE 0816

Product Make-up

  • Similar to A-2Y(L)2Y, but with petroleum-jelly filling, laminated sheath made of aluminium-coated plastic tape, and black PE outer sheath

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000829
  • ETIM 5.0 Class-Description: Signal-/telecommunications cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000829
  • ETIM 6.0 Class-Description: Signal-/telecommunications cable

Core identification code

  • According to VDE 0816,
    refer to Appendix T10

Mutual capacitance

  • At 800 Hz: max. 52 nF/km

Coupling

  • K1: 98 % <400 pF/300 m
  • K9-12: 98 % < 100 pF/300 m

Conductor cross-section in

  • 0.6 mm: 0.28 mm²
  • 0.8 mm: 0.50 mm²

Cable attenuation/attenuation

  • At 800 Hz 0.6 mm: approx. 1.0 dB/km
  • At 800 Hz 0.8 mm: approx. 0.8 dB/km

Minimum bending radius

  • 10 x outer diameter

Test voltage

  • Core/core: 500 V
  • Core/screen: 2000 V

Loop resistance

  • 0.6 mm: 130 ohm/km
  • 0.8 mm: 73.2 ohm/km

Temperature range

  • During installation: -20 °C to +50 °C
    After installation: ≤ +70 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.