Allows much faster speed and accelerations which increases the economic efficiency of the machines
Only one connection line between drive and motor-feedback system. Instead of the encoder cable integrated data pairs, quads or signal cores take over the signalling.
Less cables and reduced connection costs
Space and weight savings thanks to hybrid cable design
Increased durability under harsh conditions thanks to robust PUR outer sheath
Resistant to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media
Application range
Power drive systems in automation engineering
Connecting cable between servo controller and motor
In power chains or moving machine parts
For use in assembling & pick-and-place machinery
Particularly in wet areas of machine tools and transfer lines
For indoor and outdoor use
Product features
OCS - One Cable Solution
High oil-resistance
Abrasion and notch-resistant
Flammability: UL/CSA: VW-1, FT1 IEC/EN: 60332-1-2
Halogen-free materials
Flexible at low temperatures
Norm references / Approvals
UL AWM Style 21223 or 20233 cRU AWM I/II A/B FT1
UL File No. E63634
For use in power chains: Please comply with assembly guideline Appendix T3
Product Make-up
Extra-fine or fine wired conductor made of bare or tinned copper
Core insulation: polypropylene (PP)
Individual design depending on the item: power cores with screened control pair or bundle and specific data pairs, quads or signal cores twisted together
Non-woven wrapping
Tinned-copper braiding
PUR outer sheath, orange (RAL 2003)
Classification ETIM 5
ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
ETIM 6.0 Class-ID: EC000104
ETIM 6.0 Class-Description: Control cable
Core identification code
Details see datasheet
Conductor stranding
Power cores and brake pairs or triplets: Extra-fine wire according to VDE 0295, class 6/IEC 60228 class 6
Signal cores, data pairs or star quads: Fine-wired
Minimum bending radius
Flexing: 7.5 x outer diameter
Fixed installation: 5 x outer diameter
Nominal voltage
Power and control cores: Version 1,3 & 4: IEC U0/U 600/1000 V Version 2: IEC 300 V UL all versions: see data sheet Individual data pairs and quads: see data sheet
Test voltage
Details see datasheet
Protective conductor
G = with GN-YE protective conductor
Temperature range
Flexing: -40°C to +80°C
Fixed installation: -50°C to +80°C
Bending cycles & operation parameters
See Selection Table A2-1 in the appendix of our online catalogue
Product Datasheet
Electrica Online Product DatasheetPrepared from the current product description, catalog data and structured technical attributes.