EATON - MOELLER SDAINLM16(24VDC) SDAINLM16(24VDC) 100417 Y7-100417 EATON ELECTRIC Star-delta contactor combination, 7.5kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SDAINLM16(24VDC) 100417 Y7-100417 EATON ELECTRIC Star-delta contactor combination, 7.5kW/400V/AC3

SDAINLM16(24VDC)

100417

Y7-100417

EATON - MOELLER

1 Pcs.

Star-delta contactor combination, 7.5kW/400V/AC3 SDAINLM16(24VDC) Eaton Moeller® series SDAINL Star-delta contactor combination, 380 V 400 V: 7.5 kW, 24 V DC, DC operation

Automation > Combination of contactors
Contactors up to 170A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series SDAINL contactor combination
Catalog Number
100417
Model Code
SDAINLM16(24VDC)
EAN
4015081003945
Product Length/Depth
117 mm
Product Height
82 mm
Product Width
158 mm
Product Weight
1.19 kg
Certifications
CE
Catalog Notes
Contacts according to EN 50012

Features & Functions

Functions
Star-delta contactor

General

Application
Star-delta motor starting for contactor combinations
Product category
Contactor combinations
Suitable for
Also motors with efficiency class IE3
Used with
ETR4-51
Utilization category
AC-3: Normal AC induction motors: starting, switch off during running
Voltage type
DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C

Electrical Rating

Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
16 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
16 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
16 A
Rated operational power at AC-3, 380/400 V, 50 Hz
7.5 kW

Switching time

Changeover time
20 s, max.

Magnet system

Duty factor
100 %
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
24 V

Communication

Connection
Screw terminals

Contacts

Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
3

Design verification

Equipment heat dissipation, current-dependent Pvid
3.89 W
Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
9.28 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.