EATON - MOELLER SDAINLM55(RDC24) SDAINLM55(RDC24) 100421 Y7-100421 EATON ELECTRIC Star-delta contactor combination, 30kW/400V/AC3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SDAINLM55(RDC24) 100421 Y7-100421 EATON ELECTRIC Star-delta contactor combination, 30kW/400V/AC3

SDAINLM55(RDC24)

100421

Y7-100421

EATON - MOELLER

1 Pcs.

Star-delta contactor combination, 30kW/400V/AC3 SDAINLM55(RDC24) Eaton Moeller® series SDAINL Star-delta contactor combination, 380 V 400 V: 30 kW, 24 V DC, DC operation Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 55 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 15 kW, 380 V 400 V: P= 30 kW, 500 V: P= 37 kW, 660 V 690 V: P= 30 kW, Max. changeover time: 20 s, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Individual components of the combination Mains contactor Q11: DILM32-10 , + DILA-XHI20, Delta contactor Q15: DILM32-01, + DILA-XHI20 Part no., Star contactor Q13: DILM25-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.

Automation > Combination of contactors
Contactors up to 170A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series SDAINL contactor combination
Catalog Number
100421
Model Code
SDAINLM55(RDC24)
EAN
4015081003983
Product Length/Depth
138 mm
Product Height
95 mm
Product Width
158 mm
Product Weight
1.93 kg
Certifications
CE
Catalog Notes
Contacts according to EN 50012

Product specifications

Electrical connection type for auxiliary- and control-current circuit
Screw connection
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Used with
ETR4-51
Utilization category
AC-3: Normal AC induction motors: starting, switch off during running
Connection
Screw terminals
Ambient operating temperature - max
60 °C
Ambient operating temperature - min
-25 °C
Equipment heat dissipation, current-dependent Pvid
17.9 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
6 W
Application
Star-delta motor starting for contactor combinations
Product category
Contactor combinations
Electrical connection type of main circuit
Screw connection
Voltage type
DC
Degree of protection
IP00
NEMA Other
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
3
Number of contacts (normally closed) as main contact
0
Number of main contacts (normally open contact)
9
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Duty factor
100 %
Changeover time
20 s, max.
Functions
Star-delta contactor
Rated control supply voltage (Us) at DC - max
24 V
Rated control supply voltage (Us) at DC - min
24 V
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
55 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
55 A
Rated operational current for specified heat dissipation (In)
55 A
Rated operational power at AC-3, 380/400 V, 50 Hz
30 kW
Rated operational power (NEMA)
0 kW
Static heat dissipation, non-current-dependent Pvs
3.7 W
Suitable for
Also motors with efficiency class IE3
Rated operational power at AC-3, 500 V, 50 Hz
37 kW
Rated operational power at AC-3, 690 V, 50 Hz
30 kW
Actuating voltage
24 V DC
Number of auxiliary contacts (change-over contacts)
0
Voltage type of operating voltage
AC
Operating voltage at AC, 50 Hz - min
24 V
Operating voltage at AC, 50 Hz - max
690 V
Operating voltage at AC, 60 Hz - min
24 V
Operating voltage at AC, 60 Hz - max
690 V
Operating voltage at DC - min
0 V
Operating voltage at DC - max
0 V

ETIM for 100421 Low-voltage industrial controls and switchgear (EC000010)
Feature Name Feature Value
Function (EF000030) Star-delta contactor
Suitable for rail mounting (EF003972) No
Rated control supply voltage AC 50 Hz (EF003978) 0 V
Rated control supply voltage AC 60 Hz (EF003979) 0 V
Rated control supply voltage DC (EF003980) 24 V
Voltage type for actuating (EF008242) DC
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 9
Type of electrical connection of main circuit (EF006819) Screw connection
Voltage type (operating voltage) (EF005294) AC
Operating voltage AC 50 Hz (EF008206) 24 V
Operating voltage AC 60 Hz (EF008207) 24 V
Operating voltage DC (EF008208) 0 V
Rated operation current Ie at AC-1, 400 V (EF001393) 55 A
Rated operation current Ie at AC-3, 400 V (EF001392) 55 A
Rated operation power at AC-3, 400 V (EF001364) 30 kW
Rated operation power NEMA (EF011960) 0 kW
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 3
Number of auxiliary contacts as change-over contact (EF003531) 0
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Degree of protection (IP) (EF005474) IP00
Degree of protection (NEMA) (EF011959) Other
Width (EF000008) 158 mm
Height (EF000040) 95 mm
Depth (EF000049) 138 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.