EATON - MOELLER SWD4-8SF2-5 SWD4-8SF2-5 116022 Y7-116022 EATON ELECTRIC External device plug, SmartWire-DT, at ribbon cable for connecti.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SWD4-8SF2-5 116022 Y7-116022 EATON ELECTRIC External device plug, SmartWire-DT, at ribbon cable for connecti..

SWD4-8SF2-5

116022

Y7-116022

EATON - MOELLER

10 Pcs.

External device plug, SmartWire-DT, at ribbon cable for connection of SWD module SWD4-8SF2-5 External device plug, 8-Pole can be attached at any arbitrary place on the ribbon cable. The functional elements of arbitrarily many SmartWire-DT cards can be attached to the external device plug.

Automation > Accessories/spare parts for controls
Smartwire Darwin

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton SWD4 Accessory External device plug
Catalog Number
116022
Model Code
SWD4-8SF2-5
EAN
4015081157624
Product Length/Depth
17 mm
Product Height
36 mm
Product Width
15 mm
Product Weight
0.006 kg
Certifications
CSA File No.: 2324643
IEC/EN 61131-2
UL File No.: E29184
EN 50178
CSA Class No.: 3211-07
UL
UL Category Control No.: NKCR
CSA
Catalog Notes
not relevant

Features & Functions

Functions
For connecting the ribbon cable to SmartWire-DT modules in the control panel

General

Degree of protection
IP20 (according to IEC/EN 60529, EN 50178, VBG 4)
IP20
Product category
SmartWire-DT accessories

Ambient conditions, mechanical

Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - min
-25 °C
Operating temperature - max
55 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)

Electrical rating

Power loss
0 W

Communication

Connection to SmartWire-DT
Yes
Connection type
Socket, 8-pole

Input/Output

Number of insertion cycles
200

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 116022 PLC's (EC002584)
Feature Name Feature Value
Type of electrical accessory/spare part (EF005722) Plug
Type of mechanical accessory/spare part (EF005994) Other
Accessory (EF013236) Yes
Spare part (EF013237) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.