034825 RTR-NZM10 Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: electrical remote switching and manual tripping (push to trip) are still possible. Can be used for: NZM2, NZM2-4, N2, N2-4, NS2, NZM3, NZM3-4, N3, N3-4, NS3, NZM4, NZM4-4, N4, N4-4, NS4, NZM2-NA, NZM2-4-NA, NZM3-NA, NZM4-NA

Automation > Cover for distribution board
Circuit Breakers NZM Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Protection cover
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: electrical remote switching and manual tripping (push to trip) are still possible. Can be used for: NZM2, NZM2-4, N2, N2-4, NS2, NZM3, NZM3-4, N3, N3-4, NS3, NZM4, NZM4-4, N4, N4-4, NS4, NZM2-NA, NZM2-4-NA, NZM3-NA, NZM4-NA
[

Delivery program

Product range
Accessories
Accessories
Protective cover
Standard/Approval
IEC
Construction size
NZM3
Description

IP54 degree of protection if remote operator is routed through

Number of poles
3/4 pole
For use with
NZM2-XR
NZM2-XRD
NZM3-XR
NZM4-XR
Project planning information
Electrical remote switching and manual tripping (push to trip) are still possible.
,

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

Distribution boards (EG000023) / Cover for distribution board (EC000775)
Electric engineering, automation, process control engineering / Electrical installation, device / Electrical distribution system (incl. small distribution board) / Cover for distribution board ([email protected] [ACN397011])
Height
70 mm
Width
265 mm
Depth
275 mm
Number of rows
0
Material
Plastic
Hinging
Yes
Quick locking
Yes
Degree of protection (IP)
IP54
Colour
Other
Transparent
Yes
,

Dimensions

]

ETIM for 034825 Distribution boards (EC000775)
Feature Name Feature Value
Height (EF000040) 70 mm
Width (EF000008) 265 mm
Depth (EF000049) 275 mm
Material (EF002169) Plastic
Hinging (EF001076) Yes
Quick locking (EF001146) Yes
Degree of protection (IP) (EF005474) IP54
Colour (EF000007) Other
Transparent (EF006243) Yes