Mounting plate for IZM58, W=1200mm IZM58 mounting plate, width 1200 mm, mounting material, galvanized sheet steel, for mounting IZM58 units

Automation > Mounting plate for distribution board
Enclosures

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Fuse-link, low voltage, 12 A, AC 600 V, DC 170 V, 33.3 x 10.4 mm, G, UL, CSA, time-delay
Fuse, Fuse-link, low voltage, 12 A, AC 600 V, DC 170 V, 33.3 x 10.4 mm, G, UL, CSA, time-delay, cylindrical, size-rejecting, fusible branch panelboards, HVAC branch circuit protection, UL 248-5, Breaking Capacity 100 kA, time-delay 12 seconds (minimum) at 200% of rated current
[

Delivery program

Product range
Fuse
Basic function
Fuse-link
Field of application
low voltage
Rated current [I]
12 A
Rated voltage
AC 600 V
DC 170 V
Size
33.3 x 10.4 mm
Utilization category
G
Description
size-rejecting
Breaking Capacity
100 kA
usable for size/applications
fusible branch panelboards, HVAC branch circuit protection
Release characteristic [class]
time-delay
Standard/Approval
UL
CSA
Shape
cylindrical
Standards/Regulations
UL 248-5
Time delay
time-delay 12 seconds (minimum) at 200% of rated current
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Cylindrical fuse (EC002704)
Electric engineering, automation, process control engineering / Electrical installation, device / Safety fuse inserts / Cylindrical fuse (safety fuse) ([email protected] [AFZ797013])
Size
Other
Rated voltage
600 - 600 V
Rated voltage
Other
Voltage type
AC/DC
Utilization category
Other
Rated operating frequency
45 - 62 Hz
Nominal current
12 A
With striker
No
Release characteristic
G
Breaking capacity
100 kA
]

ETIM for 115156 Power distribution systems (EC000213)
Feature Name Feature Value
Height (EF000040) 115 mm
Width (EF000008) 370 mm
Material (EF002169) Steel
Surface protection (EF000139) Galvanised
Perforated (EF000115) true

Product Datasheet