View larger
Z-MS-4,0/2
248396
Y7-248396
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Distribution parts |
| Catalog Number | 248396 |
| Model Code | Z-MS-4,0/2 |
| EAN | 4015082483968 |
| Product Length/Depth | 80 mm |
| Product Height | 75 mm |
| Product Width | 36 mm |
| Product Weight | 0.244 kg |
| Compliances | RoHS conform |
| Actuator type | Rocker lever |
| Switch off technique | Magnetic |
| Adjustment range short-term delayed short-circuit release - min | 40 A |
| Adjustment range undelayed short-circuit release - max | 52 A |
| Adjustment range undelayed short-circuit release - min | 40 A |
| Heat dissipation per pole, current-dependent | 1.95 W |
| Overload release current setting - max | 4 A |
| Overload release current setting - min | 2.5 A |
| Rated operating power at AC-3, 230 V | 0 kW |
| Rated operating power at AC-3, 400 V | 1.5 kW |
| Rated operating voltage (Ue) - max | 400 V |
| Rated operating voltage (Ue) - min | 400 V |
| Rated operational current for specified heat dissipation (In) | 4 A |
| Rated short-circuit breaking capacity at 400 V AC | 10 kA |
| Rated uninterrupted current (Iu) | 4 A |
| Fitted with: | Thermal protection |
| Degree of protection | IP20 |
| Equipment heat dissipation, current-dependent | 3.9 W |
| Device construction | Complete device in housing |
| Electrical connection type of main circuit | Screw connection |
| Number of poles | Two-pole |
| Feature Name | Feature Value |
|---|---|
| Overload release current setting (EF002336) | 2.5 A |
| Adjustment range undelayed short-circuit release (EF007131) | 40 A |
| With thermal overload protection (EF006233) | Yes |
| Phase failure sensitive (EF007400) | No |
| Switch off technique (EF007007) | Magnetic |
| Rated operating voltage (EF001435) | 400 V |
| Rated permanent current Iu (EF001389) | 4 A |
| Rated operation power at AC-3, 230 V (EF007025) | 0 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 1.5 kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Type of control element (EF006976) | Rocker lever |
| Device construction (EF008240) | Complete device in housing |
| With integrated auxiliary switch (EF001387) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 2 |
| Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) | 10 kA |
| Degree of protection (IP) (EF005474) | IP20 |
| Height (EF000040) | 75 mm |
| Width (EF000008) | 36 mm |
| Depth (EF000049) | 80 mm |