EATON - MOELLER PLN4-C6/1N-MW PLN4-C6/1N-MW 263189 Y7-263189 EATON ELECTRIC Over current switch, 6A, 1pole+N, type C characteristic View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLN4-C6/1N-MW 263189 Y7-263189 EATON ELECTRIC Over current switch, 6A, 1pole+N, type C characteristic

PLN4-C6/1N-MW

263189

Y7-263189

EATON - MOELLER

12 Pcs.

Over current switch, 6A, 1pole+N, type C characteristic PLN4-C6/1N-MW Miniature circuit breaker (MCB), 6 A, 1p+N, characteristic: C Miniature circuit breaker (MCB), PLN4, 1-pole+N, tripping characteristic: C, rated current In: 6 A, rated switching capacity according to IEC/EN 60898-1: 4.5 kA, Switchgear for residential and commercial applications

Automation > Miniature circuit breaker (MCB)
Modular Switchgear - Tertiary

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Miniature circuit breaker (MCB), 6 A, 1p+N, characteristic: C
Miniature circuit breaker (MCB), PLN4, 1-pole+N, tripping characteristic: C, rated current In: 6 A, rated switching capacity according to IEC/EN 60898-1: 4.5 kA, Switchgear for residential and commercial applications

General specifications
Product name
Eaton Moeller series xPole - PLN4 MCB
Part no.
PLN4-C6/1N-MW
EAN
4015082631895
Product Length/Depth
80 millimetre
Product height
75 millimetre
Product width
17.5 millimetre
Product weight
0.111 kilogram
Compliances
RoHS conform
Product Tradename
xPole - PLN4
Product Type
MCB
Product Sub Type
None
Delivery program
Application
Switchgear for residential and commercial applications
xPole - Switchgear for residential and commercial applications
Number of poles
Single-pole + N
Number of poles (total)
2
Number of poles (protected)
1
Tripping characteristic
C
Release characteristic
C
Amperage Rating
6 A
Type
Miniature circuit breaker
PLN4
Technical Data - Electrical
Voltage type
AC
Rated operational voltage (Ue) - max
230 V
Rated insulation voltage (Ui)
440 V
Rated impulse withstand voltage (Uimp)
4 kV
Frequency rating - min
50 Hz
Frequency rating - max
60 Hz
Rated switching capacity (IEC/EN 60898-1)
4.5 kA
Rated short-circuit breaking capacity (EN 60898) at 230 V
4.5 kA
Rated short-circuit breaking capacity (EN 60898) at 400 V
4.5 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
0 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
0 kA
Overvoltage category
III
Pollution degree
2
Technical Data - Mechanical
Width in number of modular spacings
1
Built-in depth
70.5 mm
Degree of protection
IP20
Connectable conductor cross section (solid-core) - min
1 mm²
Connectable conductor cross section (solid-core) - max
16 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (multi-wired) - max
16 mm²
Design verification as per IEC/EN 61439 - technical data
Rated operational current for specified heat dissipation (In)
6 A
Heat dissipation per pole, current-dependent
0 W
Equipment heat dissipation, current-dependent
1.7 W
Static heat dissipation, non-current-dependent
0 W
Heat dissipation capacity
0 W
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
75 °C
Additional information
Current limiting class
3
Features
Concurrently switching N-neutral
Additional equipment possible
Special features
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Used with
Miniature circuit breaker
PLN4

Technical data ETIM 9.0

Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)
Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) (ecl@ss13-27-14-19-01 [AAB905019])
Built-in depth
70.5 mm
Release characteristic
C
Number of poles (total)
2
Number of protected poles
1
Rated current
6 A
Rated voltage
230 V
Rated insulation voltage Ui
440 V
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
4.5 kA
Voltage type
AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
4.5 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
0 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
0 kA
Frequency
50 - 60 Hz
Power loss
1.1 W
Current limiting class
3
Flush-mounted installation
No
Concurrently switching neutral conductor
Yes
Over voltage category
3
Pollution degree
2
Additional equipment possible
Yes
Width in number of modular spacings
1
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 - 75 °C
Connectable conductor cross section multi-wired
1 - 16 mm²
Connectable conductor cross section solid-core
1 - 16 mm²
Explosion-proof
No

ETIM for 263189 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 70.5 mm
Release characteristic (EF000889) C
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 1
Rated current (EF000227) 6 A
Rated voltage (EF000228) 230 V
Rated insulation voltage Ui (EF001366) 440 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) 4.5 kA
Voltage type (EF000187) AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 4.5 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 0 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 0 kA
Frequency (EF000416) 50 Hz
Power loss (EF005387) 1.1 W
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) Yes
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Additional equipment possible (EF008148) Yes
Width in number of modular spacings (EF002950) 1
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 1 mm²
Connectable conductor cross section solid-core (EF007337) 1 mm²
Explosion-proof (EF004663) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.