EATON - MOELLER SPBT12-280/1 SPBT12-280/1 158306 Y7-158306 EATON ELECTRIC Lightning current and surge arresters, 12, 5 kA, L-(SU) N View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SPBT12-280/1 158306 Y7-158306 EATON ELECTRIC Lightning current and surge arresters, 12, 5 kA, L-(SU) N

SPBT12-280/1

158306

Y7-158306

EATON - MOELLER

1 Pcs.

Lightning current and surge arresters, 12, 5 kA, L-(SU) N SPBT12-280/1 Eaton Moeller series xPole - SPBT12 Surge Protection Device. Lightning current and surge arresters, 12, 5 kA, L-(SU) N For protecting consumer systems against transient overvoltages caused by direct and indirect lightning strikes and switching operations, use in accordance with IEC 60364-5-53 section 534, iI according to IEC 61643-1, SPD-type T1, T2 according to EN 61643-11, lightning protection classes III and IV as per IEC 62305

Automation > Combined arrester for power supply systems
Modular Switchgear – Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller series xPole - SPBT12 Surge protection device
Catalog Number
158306
Model Code
SPBT12-280/1
EAN
4015081548842
Product Length/Depth
80 mm
Product Height
65 mm
Product Width
17.5 mm
Product Weight
0.137 kg
Compliances
RoHS conform

Delivery program

Application
Number of poles
Single-pole
Type
Surge arrester

Technical data - electrical

Voltage protection level
1.5 KV
Voltage protection level (DC+ - DC-)
0 KV
Voltage protection level (DC+/DC- - PE)
0 KV
Voltage protection level (L-N)
0 KV
Voltage protection level (L-PE)
1.5 KV
Voltage protection level (N-PE)
0 KV
Nominal voltage at AC
280 V
Nominal voltage at DC
0 V
Continuous voltage at AC - max
280 V
Continuous voltage at DC - max
0 V
PV-voltage - max
0 V
Lightning impulse current (10/350 µs)
12.5 kA
Follow current extinguishing capability
0 kA
Signalling at the device
Optic
Specific energy (W/R)
39.1 kJ/Ohm

Technical data - mechanical

Frame
1 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
Conductor cross section (flexible, fine-strand) - max
35 mm²
Conductor cross section (solid, solid-strand) - max
25 mm²
Degree of protection
IP20

Additional information

System configuration type
TN
Other
TN-S
Test class
Type 1 + 2

ETIM for 158306 Earthing, lightning and surge protection (EC001457)
Feature Name Feature Value
System configuration DC (EF009926) No
System configuration IT (EF009927) No
System configuration TN (EF009928) Yes
System configuration TN-C (EF009929) No
System configuration TN-C-S (EF009933) No
System configuration TN-S (EF009930) Yes
System configuration TT (EF009931) No
System configuration other (EF009932) Yes
Number of poles (EF001391) 1
Lightning impulse current (10/350 µs) (EF000421) 12.5 kA
Max. continuous voltage AC (EF004198) 280 V
Max. continuous voltage DC (EF004777) 0 V
Nominal voltage AC (EF004220) 280 V
Nominal voltage DC (EF004221) 0 V
Max. PV-voltage (EF008795) 0 V
Voltage protection level (EF003525) 1.5 kV
Voltage protection level L-N (EF004236) 0 kV
Voltage protection level L-PE (EF012276) 1.5 kV
Voltage protection level N-PE (EF008796) 0 kV
Voltage protection level (DC+ - DC-) (EF009643) 0 kV
Voltage protection level (DC+/DC- - PE) (EF009644) 0 kV
Follow current extinguishing capability (EF004193) 0 kA
Specific energy (W/R) (EF009797) 39.1 kJ/Ohm
Max. overcurrent protection device, parallel connection (fuse) (EF015962) 0 A
Max. overcurrent protection device, series connection (fuse) (EF015963) 160 A
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) 1 modular spacing
Max. conductor cross section solid (solid, stranded) (EF008827) 25 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 35 mm²
Remote signalling (EF004192) No
Signalling at the device (EF004241) Optic
Test class (EF004228) Type 1 + 2
Integrated backup fuse (EF008797) No
Energy-coordinated protection effect with regard to the terminal equipment (EF009798) No
Voltage switching spark gap technology (EF016003) No
Overcurrent protected voltage tapping (EF016004) No
Degree of protection (IP) (EF005474) IP20

Product Datasheet