EATON - MOELLER ETR2-21 ETR2-21 262687 Y7-262687 EATON ELECTRIC Timing relay, 0.05s-100h, 24-240VAC 50/60Hz, 24-48VDC, 1W, fleeting .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ETR2-21 262687 Y7-262687 EATON ELECTRIC Timing relay, 0.05s-100h, 24-240VAC 50/60Hz, 24-48VDC, 1W, fleeting ..

ETR2-21

262687

Y7-262687

EATON - MOELLER

1 Pcs.

Timing relay, 0.05s-100h, 24-240VAC 50/60Hz, 24-48VDC, 1W, fleeting contact on energization ETR2-21 Eaton Moeller® series ETR2 Timing relay, 0.05s-100h, 24-240VAC 50/60Hz, 24-48VDC, 1W, fleeting contact on energization ETR2 electronic timing relays, 17.5 mm wide, time range 0.05s-100h, 1 changeover contacts fleeting contact on energization

Automation > Timer relay
Relay timers (KETR, KEMR, KESR)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series ETR2 Timing relay
Catalog Number
262687
Model Code
ETR2-21
EAN
4015082626877
Product Length/Depth
63 mm
Product Height
70 mm
Product Width
17.5 mm
Product Weight
0.05 kg
Certifications
CSA File No.: UL report valid
IEC/EN 60947-5-1
UL File No.: E29184
CSA Class No.: 3211-03
IEC/EN 61812-1
Certified by UL for use in Canada
UL Category Control No.: NKCR, NKCR7
CSA-22.2 No. 14
UL
CE
UL 508

Features & Functions

Electric connection type
Screw connection
Functions
Fixed timing function
Fleeting contact on energization

General

Degree of protection
IP20
Number of contacts (change-over contacts)
1
Product category
ETR2 timing relays
Suitable for
DIN rail (top hat rail) mounting
Time range - min
0.05 s
Time range - max
360000 s
Type
Timer relay
Voltage type
AC/DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C

Electrical rating

Mains voltage tolerance
24 - 240 V AC (at 50/60 Hz)
24 - 48 V DC
Nominal current
3 A
Rated operational current (Ie)
3 A at 230 V (NC)
3 A at 230 V (NO)
4 A at AC-15, 220 V 230 V 240 V

Magnet system

Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Rated control supply voltage (Us) at AC, 50 Hz - max
240 V
Rated control supply voltage (Us) at AC, 60 Hz - min
24 V
Rated control supply voltage (Us) at AC, 60 Hz - max
240 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
240 V

Design verification

Heat dissipation capacity Pdiss
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 262687 Relays (EC001439)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
Complete with socket (EF003359) No
Suitable for DIN rail (top hat rail) mounting (EF007250) Yes
Suitable for front mounting (EF020288) No
Pluggable on auxiliary contact block (EF006952) No
Function delay-on energization (EF003374) No
Function delay on de-energization (EF003401) No
Function floating contact on energization (EF003378) Yes
Function floating contact on de-energization (EF003402) No
Function star-delta (EF003380) No
Function pulse shaping (EF003403) No
Function flashing, starting with pause, fixed time (EF003363) No
Function flashing, starting with pulse, fixed time (EF003364) No
Clock function, starting with pause, variable (EF003365) No
Clock function, starting with pulse, variable (EF003366) No
Time range (EF003384) 0.05 s
Remote operation possible (EF003361) No
Suitable as remote control (EF003362) No
Rated control supply voltage AC 50 Hz (EF003978) 24 V
Rated control supply voltage AC 60 Hz (EF003979) 24 V
Rated control supply voltage DC (EF003980) 24 V
Voltage type for actuating (EF008242) AC/DC
Number of outputs, undelayed, normally closed contact (EF006835) 0
Number of outputs, undelayed, normally open contact (EF006836) 0
Number of outputs, undelayed, change-over contact (EF006837) 1
Number of outputs, delayed, normally closed contact (EF006838) 0
Number of outputs, delayed, normally open contact (EF006839) 0
Number of outputs, delayed, change-over contact (EF006840) 0
Outputs, reversible delayed/undelayed (EF006988) No
With semiconductor output (EF003373) No
Operating voltage AC 50 Hz (EF008206) 24 V
Operating voltage AC 60 Hz (EF008207) 24 V
Operating voltage DC (EF008208) 24 V
Voltage type (operating voltage) (EF005294) AC/DC
Nominal current (EF000001) 3 A
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 17.5 mm
Height (EF000040) 70 mm
Depth (EF000049) 63 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.