EATON - MOELLER LZMC1-ASF50-I LZMC1-ASF50-I 111882 Y7-111882 EATON ELECTRIC Circuit-breaker, 3 p, 50A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LZMC1-ASF50-I 111882 Y7-111882 EATON ELECTRIC Circuit-breaker, 3 p, 50A

LZMC1-ASF50-I

111882

Y7-111882

EATON - MOELLER

1 Pcs.

Circuit-breaker, 3 p, 50A LZMC1-ASF50-I

Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers LZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Circuit-breaker, 3 p, 50A

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Circuit breaker for power transformer, generator and system protection ([email protected] [AJZ716013])
Rated permanent current Iu
50 A
Rated voltage
690 - 690 V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36 kA
Overload release current setting
40 - 50 A
Adjustment range short-term delayed short-circuit release
0 - 0 A
Adjustment range undelayed short-circuit release
300 - 500 A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Frame clamp
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
With under voltage release
No
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
No
Degree of protection (IP)
IP20

ETIM for 111882 Low-voltage industrial controls and switchgear (EC000228)
Feature Name Feature Value
Rated permanent current Iu (EF001389) 50 A
Rated voltage (EF003977) 690 V
Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) 36 kA
Overload release current setting (EF002336) 40 A
Adjustment range short-term delayed short-circuit release (EF007129) 0 A
Adjustment range undelayed short-circuit release (EF007131) 300 A
Device construction (EF008240) Built-in device fixed built-in technique
Integrated earth fault protection (EF007296) No
Type of electrical connection of main circuit (EF006819) Frame clamp
Suitable for DIN rail (top hat rail) mounting (EF007250) No
DIN rail (top hat rail) mounting optional (EF008904) Yes
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) No
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Front
Type of control element (EF006976) Rocker lever
Complete device with protection unit (EF008906) Yes
Motor drive integrated (EF006697) No
Motor drive optional (EF007386) No
Degree of protection (IP) (EF005474) IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.