NZMB2-M160
265716
Y7-265716
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Moeller series NZM molded case circuit breaker thermo-magnetic |
| Catalog Number | 265716 |
| Model Code | NZMB2-M160 |
| EAN | 4015082657161 |
| Product Length/Depth | 149 mm |
| Product Height | 184 mm |
| Product Width | 105 mm |
| Product Weight | 2.327 kg |
| Compliances | RoHS conform |
| Certifications | IEC/EN 60947 IEC |
| Amperage Rating | 160 A |
| Voltage rating | 440 V - 440 V |
| Circuit breaker frame type | NZM2 |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Fitted with: | Thermal protection |
| Pollution degree | 3 |
| Mounting Method | Fixed Built-in device fixed built-in technique |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Equipment heat dissipation, current-dependent | 38.4 W |
| Utilization category | A (IEC/EN 60947-2) |
| Isolation | 500 V AC (between auxiliary contacts and main contacts) 300 V AC (between the auxiliary contacts) |
| Ambient operating temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient storage temperature - min | 40 °C |
| Protection against direct contact | Finger and back-of-hand proof to VDE 0106 part 100 |
| Rated insulation voltage (Ui) | 690 V |
| Rated operating power at AC-3, 230 V | 45 kW |
| Rated operating power at AC-3, 400 V | 90 kW |
| Switch off technique | Thermomagnetic |
| Degree of protection | IP20 IP20 (basic degree of protection, in the operating controls area) |
| Direction of incoming supply | As required |
| Electrical connection type of main circuit | Screw connection |
| Lifespan, mechanical | 20000 operations |
| Overvoltage category | III |
| Rated operational current | 134 A (400 V AC-3) |
| Degree of protection (IP), front side | IP40 (with insulating surround) IP66 (with door coupling rotary handle) |
| Degree of protection (terminations) | IP00 (terminations, phase isolator and strip terminal) IP10 (tunnel terminal) |
| Number of poles | Three-pole |
| Terminal capacity (copper strip) | Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched) Min. 2 segments of 9 mm x 0.8 mm at box terminal Max. 10 segments of 24 mm x 0.8 mm at rear-side connection (punched) Max. 8 segments of 24 mm x 1 mm (2x) at box terminal Max. 10 segments of 16 mm x 0.8 mm at box terminal |
| Lifespan, electrical | 7500 operations at 415 V AC-1 10000 operations at 400 V AC-1 |
| Functions | Motor protection |
| Type | Circuit breaker |
| Special features |
|
| Application | Use in unearthed supply systems at 440 V |
| Shock resistance | 20 g (half-sinusoidal shock 20 ms) |
| Rated operational current for specified heat dissipation (In) | 160 A |
| Short-circuit release non-delayed setting - max | 2240 A |
| Short-circuit release non-delayed setting - min | 1280 A |
| Handle type | Rocker lever |
| Instantaneous current setting (Ii) - max | 2240 A |
| Instantaneous current setting (Ii) - min | 1280 A |
| Number of operations per hour - max | 120 |
| Overload current setting (Ir) - max | 160 A |
| Overload current setting (Ir) - min | 125 A |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz | 30 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz | 18.5 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz | 18.5 kA |
| Standard terminals | Screw terminal |
| Optional terminals | Box terminal. Connection on rear. Tunnel terminal |
| Release system | Thermomagnetic release |
| Short-circuit total breaktime | < 10 ms |
| Terminal capacity (aluminum solid conductor/cable) | 16 mm² (1x) at tunnel terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection 10 mm² - 16 mm² (2x) direct at switch rear-side connection |
| Terminal capacity (aluminum stranded conductor/cable) | 25 mm² - 50 mm² (2x) direct at switch rear-side connection 25 mm² - 50 mm² (1x) direct at switch rear-side connection 25 mm² - 185 mm² (1x) at tunnel terminal |
| Terminal capacity (control cable) | 0.75 mm² - 1.5 mm² (2x) 0.75 mm² - 2.5 mm² (1x) |
| Terminal capacity (copper busbar) | Min. 16 mm x 5 mm direct at switch rear-side connection M8 at rear-side screw connection Max. 24 mm x 8 mm direct at switch rear-side connection |
| Terminal capacity (copper solid conductor/cable) | 6 mm² - 16 mm² (2x) direct at switch rear-side connection 10 mm² - 16 mm² (1x) at box terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection 6 mm² - 16 mm² (2x) at box terminal 16 mm² (1x) at tunnel terminal |
| Terminal capacity (copper stranded conductor/cable) | 25 mm² - 185 mm² (1x) direct at switch rear-side connection 25 mm² - 70 mm² (2x) direct at switch rear-side connection 25 mm² - 70 mm² (2x) at box terminal 25 mm² - 185 mm² (1x) at box terminal 25 mm² - 185 mm² (1x) at 1-hole tunnel terminal |
| Rated short-circuit breaking capacity Icu (IEC/EN 60947) at 400/415 V, 50/60 Hz | 18.5 kA |
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz | 53 kA |
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz | 53 kA |
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz | 63 kA |
| Rated impulse withstand voltage (Uimp) at auxiliary contacts | 6000 V |
| Rated impulse withstand voltage (Uimp) at main contacts | 8000 V |
| Power loss | 38.4 W |
| Feature Name | Feature Value |
|---|---|
| Overload release current setting (EF002336) | 125 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1280 A |
| With thermal overload protection (EF006233) | Yes |
| Phase failure sensitive (EF007400) | No |
| Switch off technique (EF007007) | Thermomagnetic |
| Rated operating voltage (EF001435) | 440 V |
| Rated permanent current Iu (EF001389) | 160 A |
| Rated operation power at AC-3, 230 V (EF007025) | 45 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 90 kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Type of control element (EF006976) | Rocker lever |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| With integrated auxiliary switch (EF001387) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) | 18.5 kA |
| Degree of protection (IP) (EF005474) | IP20 |
| Height (EF000040) | 184 mm |
| Width (EF000008) | 105 mm |
| Depth (EF000049) | 149 mm |