Used with
Industrial control panels
Special features
Fitted with removable smooth flanges on all 4 sidesFixing straps for wall fixingSealable cover fasteners
Type
Basic enclosureDistribution board enclosures for North AmericaPanel enclosures with cover and flangesxEnergy Safety Ci
Features
UV resistance beneath protective shield
Cover with overpressure release
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Lower part: 960 °C / cover: 850 °C
10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2.5 Lifting
30 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
Protection class 2, therefore not applicable.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
10.9.3 Impulse withstand voltage
10.9.4 Testing of enclosures made of insulating material
Meets the product standard's requirements.
Surface finishing
RAL 7035, light gray (base)
Transparent, smoky gray (cover)
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Creepage resistance
KB160, KC175 (base, to IEC 60112)
KB100, KC200 (cover, to IEC 60112)
Degree of protection
IK10
IP65 (IEC)
UL/CSA Types 1, 12, 13, 4X, indoor only
4X (NEMA)
IP65
Base type
Enclosure side plates with removable smooth flanges
Heat diss. ambient 35°C delta T:20°C wall mount individ. encl. top (IEC 60890)
Heat diss. ambient 35°C delta T: 20°C wall mount middle encl. top (IEC 60890)
Heat diss. ambient 35°C delta T:20°C wall mount starting encl. top (IEC 60890)
Heat diss. ambient 35°C delta T:35°C wall mount individ. encl. top (IEC 60890)
Heat diss. ambient 35°C delta T: 35°C wall mount middle encl. top (IEC 60890)
Heat diss. ambient 35°C delta T:35°C wall mount starting encl. top (IEC 60890)
Number of openings (flange plates)
Plate thickness (cabinet)
Plate thickness (cover/door)
Surface resistance (IEC 60093)
Width in number of modular spacings
Ambient operating temperature details
Mounting method
Surface mounted (plaster)
Suitable for
Lightning protection
Outdoor use