ABB 1SDA068136R1 1SDA068136R1 ABB XT4N 250 Ekip LSI In 250A 3p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA068136R1 ABB XT4N 250 Ekip LSI In 250A 3p F F

1SDA068136R1

068136

ABB

1 Pcs.

XT4N 250 Ekip LSI In=250A 3p F F XT4N250 Ekip LSI R250 3P F F

Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ABB EcoSolutions
ABB EcoSolutionsYes
Circular Value
Circular Design Principles Recyclability RateDesign for Closing Resource Loops - Standard EN45555 - 56.30 %
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
End of Life Instructions9AKK108468A2352
Group Waste to Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA9AKK108467A8326
Eco Transparency
Environmental Product Declaration - EPD9AKK108469A1858
9AKK108468A1898
Environmental
Environmental Information9AKK108467A6707
REACH Declaration9AKK108466A1425
RoHS Information9AKK108466A1424
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPb2291b72-aef3-4968-a1ce-94bb806ce883 Italy (IT)
Simplified SCIP75a324bb-ee32-442f-bebf-d8c1052049eb Germany (DE)
044f936e-da76-481a-8519-ed7b47efe3ef France (FR)
7ce4f487-77b6-45cd-b303-2688e44e6dc2 Sweden (SE)
1961753b-e78a-4561-95dc-3540601a750e Germany (DE)
1a515add-0f1d-4615-9fe3-3f520c3ee9ba Germany (DE)
3f5ef36a-e368-457f-bb0f-65e90563e08f France (FR)
8ecff045-f20b-4953-9ce5-9f3fdd04f98e Netherlands (NL)
04d800e7-6d48-41a7-a458-d9a5828514ee Spain (ES)
c1c5ef7d-36ef-4b9e-a68e-c95dc3452bea Netherlands (NL)
055609c0-30d5-4763-9264-a808079ac679 Poland (PL)
0ac1115c-3d66-4114-a700-881272f0522d Norway (NO)
dbd6fb7f-f984-44c9-b0bb-f81c9faf9cef Finland (FI)
b729549e-b06e-4350-a238-c36d7f4647e7 Netherlands (NL)
d620dcbb-3d83-46c2-8580-f002b6f6a9d8 Germany (DE)
d7a101b9-4e4d-4274-894d-227e0301f247 Denmark (DK)
051a7e63-1dc6-4324-beb3-00546ac8056d Germany (DE)
00a30eb2-15bd-4779-9750-90e0e25b677f Croatia (HR)
57b44da2-4e85-4f18-a6f1-5040ca106c56 Czech Republic (CZ)
b5891451-9746-4fa7-b10a-83fae960bfac Poland (PL)
1b9069a2-3ce0-435d-8f5d-71718693fb26 Netherlands (NL)
914a8870-c791-4181-b757-6e8edb05f82d Netherlands (NL)
e74edcd7-9993-4bea-baa1-3793d9ad165b Estonia (EE)
67b3f77b-0afb-4953-8ce0-b6ed11abe8a4 Greece (GR)
43b29558-97e5-4b95-9a13-1c6e24e86460 Portugal (PT)
94758f44-a808-4fd8-9d13-8fec8f8bfe5c Bulgaria (BG)
9fd8eb71-2981-4365-b175-8c1c8ac1f415 Sweden (SE)
f0f76699-090d-4612-9ef7-f24d270117d1 Poland (PL)
Ordering
Order Code US and CanadaXT4NE3250FFF000XXX
E-Number (Finland)3641037
EAN8015644696009
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width105 mm
Product Net Height160 mm
Product Net Depth / Length82.5 mm
Product Net Weight2.323 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width151 mm
Package Level 1 Height214 mm
Package Level 1 Depth / Length171 mm
Package Level 1 Gross Weight2.445 kg
Package Level 1 EAN8015644696009
Additional Information
Circuit Breaker Type to be AssociatedPower Distribution
Connecting Capacity Main CircuitBusbar 85..200 mm²
Current TypeAC
Electrical Durability120 cycles per hour
8000 cycle
Mechanical Durability240 cycles per hour
25000 cycle
Number of Poles3
Opening TimeCB with SOR 15 ms
CB with UVR 15 ms
Order Multiple1 piece
Power Lossat Rated Operating Conditions per Pole 16.40 W
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
Rated Current (In)250 A
Rated Frequency (f)50/60 Hz
Rated Voltage (Ur)690 V AC
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)1000 V AC
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
Rated Uninterrupted Current (Iu)250 A
Recommended Screw DriverMain Circuit M8
ReleaseEkip LSI
Release TypeEL
RoHS DateNA
Short-Circuit Performance LevelN
StandardsIEC60947-2
Sub-typeXT4
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque8 N·m
VersionF
CAD Dimensional Drawing1SDH002230A1003
Certificates and Declarations
ATEX CertificateNo certification needed
Data Sheet, Technical Information2CDC210017C0101
1SDC210100D0206
1SXF210033C2001
1SDC210099D0206
1SXF210034C2001
Declaration of Conformity - CE9AKK106713A5529
GL Certificate1SDL000163R0095
LR Certificate1SDL000163R0100
UL CertificateNo certification needed
VDE CertificateNo certification needed
Dimension Diagram1SDH000722R0100
Mechanical Drawings1SDH000722R0100
Wiring Diagram1SDM000068R0001
Instructions and Manuals1SDH000722R0001
1SDH000721R0506
Classifications
ETIM 7EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification CodeQ
UNSPSC39121616
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.