ABB 1SDA080839R1 1SDA080839R1 ABB XT1H 160 TMD R40 Im450 3p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA080839R1 ABB XT1H 160 TMD R40 Im450 3p F F

1SDA080839R1

080839

ABB

1 Pcs.

XT1H 160 TMD R40 Im450 3p F F

Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2347
Environmental Product Declaration - EPD9AKK108468A1890
9AKK108468A7793
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
Environmental
Environmental Information1SDL000190R0001
9AKK108467A6707
Ordering
Order Code US and CanadaXT1HE3040AFF000XXX
E-Number (Norway)4379216
EAN8015644873677
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width76.2 mm
Product Net Height130 mm
Product Net Depth / Length70 mm
Product Net Weight1 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width128 mm
Package Level 1 Height135 mm
Package Level 1 Depth / Length143 mm
Package Level 1 Gross Weight1.1 kg
Package Level 1 EAN8015644873677
Additional Information
Circuit Breaker Type to be AssociatedPower Distribution
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001295R0008
Technical
Current TypeAC/DC
Electrical Durability120 cycles per hour
8000 cycle
Mechanical Durability240 cycles per hour
25000 cycle
Number of Poles3P
Opening TimeCB with SOR 30 ms
CB with UVR 30 ms
Order Multiple1 piece
Rated Current (In)40 A
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)450 A
Rated Insulation Voltage (Ui)800 V
Rated Operational Voltage690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 80 kA
(230 V AC) 80 kA
(240 V AC) 80 kA
(380 V AC) 52.5 kA
(415 V AC) 37.5 kA
(440 V AC) 32.5 kA
(500 V AC) 25 kA
(525 V AC) 17.5 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 52.5 kA
(500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 100 kA
(230 V AC) 100 kA
(240 V AC) 100 kA
(380 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(525 V AC) 35 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 70 kA
(500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)160 A
Rated Voltage (Ur)690 V
ReleaseTMD
Release TypeTM
Setting Range28...40 A
Short-Circuit Performance LevelH
StandardsIEC60947-2
Sub-typeXT1
Terminal Connection TypeFront
Certificates and Declarations
Data Sheet, Technical Information1SDC210100D0206
1SDC210099D0206
Declaration of Conformity - CE9AKK106713A5532
Mechanical Drawings1SDH000719R0100
Wiring Diagram1SDM000068R0001
Instructions and Manuals1SDH000719R0001
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

ETIM for 1SDA080839R1 Low-voltage industrial controls and switchgear (EC000228)
Feature Name Feature Value
Rated permanent current Iu (EF001389) 40 A
Rated voltage (EF003977) 690 V
Integrated earth fault protection (EF007296) No
Type of electrical connection of main circuit (EF006819) Bolt connection
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) No
DIN rail (top hat rail) mounting optional (EF008904) No
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) No
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Front
Type of control element (EF006976) Toggle
Complete device with protection unit (EF008906) Yes
Motor drive integrated (EF006697) No
Motor drive optional (EF007386) Yes
Degree of protection (IP) (EF005474) IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.