View larger
1SDA080825R1
080825
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2347 |
| Environmental Product Declaration - EPD | 9AKK108468A1890 |
| 9AKK108468A7793 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 55.9 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 70b73566-5c09-4f10-b2cc-0fd8af696d3a Italy |
| Simplified SCIP | 0854b93e-16c6-4f92-bd09-4a09b4fb0c3a Poland |
| 68a4831e-82d5-4552-963e-dec827e5e579 Germany | |
| 62a8b299-f370-4478-8845-b6894507f841 Finland | |
| b9dc148c-dc99-469a-9472-2e566b8289ba France | |
| 6dac1336-68d7-4fd2-8eb3-8ae756914377 Germany | |
| aec0f004-1140-4faa-a475-7851f966fb9f Greece | |
| 4f27df03-cb73-40a1-a852-cb838325cbef Estonia | |
| b0e3d288-2ffb-4c7e-a7df-ea04f1575068 Netherlands | |
| ede9ed39-fa88-427a-99bc-5aec1d73328c France | |
| dac09b8c-37d9-467a-9273-32d07bbd122f Spain | |
| 91070ec8-7e90-4fc5-aa52-f747f90ca432 Hungary | |
| d11e8361-6579-45c0-8e6d-54166c2ab4cf Germany | |
| 21c4f589-17f2-45e3-83f2-78b7ac25dff0 Germany | |
| db586589-5dab-4ca0-89a2-ee5ab613b135 Hungary | |
| 03e9c449-ca09-4ae3-b430-15f8e93fbcee Poland | |
| e16418e3-f7dc-408f-84d1-a97965447940 Sweden | |
| 5e1f8532-b10e-4e05-93b1-6689e00a134a Sweden | |
| dde3433c-87d2-4bbc-922e-844673dbce2d Poland | |
| 167f9b68-d46d-418a-8115-eff1b281bf84 Bulgaria | |
| 3ed4a088-6cfe-49d6-8bcc-b57f603440d2 Portugal | |
| e75d34d0-b69b-4264-9aa6-c69c2854fec6 Czech Republic | |
| 23dcc95d-4c30-4d0a-8d85-663bb470c6f8 Denmark | |
| 9bd98cf6-0957-4aaa-9b0c-97fd1dfc3bf2 Germany | |
| c2c81bf2-7c19-4867-a189-93eebb70cdeb Croatia | |
| ea70dde0-7955-48fc-b76e-7537599cde43 Belgium | |
| a6bd1835-7000-4145-af26-9ddc74d06c47 Norway | |
| c81b564d-bd62-4c85-81e1-fbad61b3fdb9 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT1CE3016AFF000XXX |
| E-Number (Finland) | 3638771 |
| E-Number (Norway) | 4379200 |
| EAN | 8015644873431 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 76.2 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 128 mm |
| Package Level 1 Height | 135 mm |
| Package Level 1 Depth / Length | 143 mm |
| Package Level 1 Gross Weight | 1.1 kg |
| Package Level 1 EAN | 8015644873431 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0008 |
| Technical | |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Rated Current (In) | 16 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 450 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 40 kA |
| (230 V AC) 40 kA | |
| (240 V AC) 40 kA | |
| (380 V AC) 25 kA | |
| (415 V AC) 25 kA | |
| (440 V AC) 12.5 kA | |
| (500 V AC) 9 kA | |
| (525 V AC) 8 kA | |
| (690 V AC) 4 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 3 Poles in Series 25 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 40 kA |
| (230 V AC) 40 kA | |
| (240 V AC) 40 kA | |
| (380 V AC) 25 kA | |
| (415 V AC) 25 kA | |
| (440 V AC) 25 kA | |
| (500 V AC) 18 kA | |
| (525 V AC) 8 kA | |
| (690 V AC) 4 kA | |
| (250 V DC) 2 Poles in Series 25 kA | |
| (500 V DC) 3 Poles in Series 25 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Release | TMD |
| Release Type | TM |
| Setting Range | 11.2...16 A |
| Short-Circuit Performance Level | C |
| Standards | IEC60947-2 |
| Sub-type | XT1 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5532 |
| Mechanical Drawings | 1SDH000719R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000719R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |