View larger
2CTB803871R2300
803871
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| Environmental Product Declaration - EPD | 9AKK108468A7418 |
| Technical | |
| Type of Low Voltage Distribution System | TT |
| TN-C | |
| TN-S | |
| Suitable For | To protect the systems against the transient overvoltage (lightning) |
| Nominal AC Voltage of the System (Uo) | 230 / 400 V |
| Maximum Continuous Operating Voltage (Uc) | (L-PE) 275 V |
| Temporary Overvoltage Test Value (UT) | 337 V |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 100 kA |
| Discharge Current | Nominal (8 / 20 µs) 20 kA |
| I (max, 8 / 20 µs) 40 kA | |
| Impulse Current | I (imp, 10 / 350 µs) 2 kA |
| Short Circuit Withstand Icc | 100 kA |
| Arrester Class | II |
| Number of Protected Poles | 1 |
| Number of Poles | 1P |
| Number of Conductors | 1 |
| Transmission Standard | Optic |
| Version | Plug-in |
| Product Type | QS |
| Options Provided | Residential, commercial building. |
| Auxiliary Circuit Load | Minimum - |
| Maximum - | |
| Preventive Maintenance Feature | No |
| Status Indicator | Yes |
| Fuse Size | 1 modular spacing |
| Cross-Section (Across) | Maximum Conductor Solid-Stranded 25 mm² |
| Maximum Conductor Flexible 16 mm² | |
| Electrical | |
| Rated Voltage (Ur) | 230 V AC |
| Voltage Protection Level ( Up) | 1.25 kV |
| (L-N) 1.25 kV | |
| (N-PE) 1.25 kV | |
| Power Loss | Total 8 mW |
| Material Compliance | |
| RoHS Declaration | 9AKK108466A4410 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20230707 |
| REACH Declaration | 9AKK107492A1906 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20231212 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Degree of Protection | IP20 |
| Maximum Operating Altitude Permissible | Without Derating 5000 |
| Dimensions | |
| Width in Number of Modular Spacings | 1 |
| Product Net Width | 17.8 mm |
| Product Net Height | 88 mm |
| Product Net Depth / Length | 58 mm |
| Product Net Weight | 0.12 kg |
| Engineering | |
| EPLAN Data | 9AAC183885_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 145 g |
| E-Number (Finland) | 3211204 |
| E-Number (Norway) | 1672328 |
| Certificates and Declarations | |
| CB Certificate | 2CTC432024G1701 |
| CQC Certificate | 9AKK107680A1974 |
| Declaration | 2CTC432056G1701 |
| Declaration of Conformity - CE | 9AKK108466A4410 |
| Installation | |
| Instructions and Manuals | 2CTC432097M1701 |
| Mounting Type | DIN-Rail |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CTC432208D0201 |
| Mechanical Drawings | 2CTC800021F0100.pdf |
| 2CTC800021F0101.dxf | |
| 2CTC800021F0102.stp | |
| 2CTC800021F0103.igs | |
| External Classifications and Standards | |
| ETIM 9 | EC000941 - Surge protection device for power supply systems |
| ETIM 10 | EC000941 - Surge protection device for power supply systems |
| UNSPSC | 39121610 |
| eClass | V11.0 : 27130805 |
| Object Classification Code | 141DCC |
| Standards | IEC 61643-11 / EN 61643-11 |
| Feature Name | Feature Value |
|---|---|
| System configuration DC (EF009926) | No |
| System configuration IT (EF009927) | No |
| System configuration TN (EF009928) | No |
| System configuration TN-C (EF009929) | No |
| System configuration TN-C-S (EF009933) | No |
| System configuration TN-S (EF009930) | No |
| System configuration TT (EF009931) | No |
| System configuration other (EF009932) | No |
| Number of conductors (without earthing) (EF001148) | 1 |
| Nominal discharge surge current (8/20) (EF004214) | 20 kA |
| Max. discharge surge current (8/20) (EF012274) | 20 kA |
| Nominal voltage AC (EF004220) | 230 V |
| Max. continuous voltage AC (EF004198) | 275 V |
| Voltage protection level (EF003525) | 1.25 kV |
| Voltage protection level L-N (EF004236) | 1.25 kV |
| Voltage protection level N-PE (EF008796) | 1.25 kV |
| Max. overcurrent protection device, parallel connection (fuse) (EF015962) | 125 A |
| Max. overcurrent protection device, series connection (fuse) (EF015963) | 125 A |
| Short-circuit breaking capacity (Isccr) (EF012627) | 100 kA |
| Integrated short-circuit protection (EF016000) | No |
| Integrated backup fuse (EF008797) | No |
| Leakage-current free (EF016002) | No |
| Mounting method (EF000003) | Other |
| Construction size (EF002566) | 1 modular spacing |
| Max. conductor cross section solid (solid, stranded) (EF008827) | 25 mm² |
| Max. conductor cross section flexible (fine-strand) (EF008828) | 16 mm² |
| With remote signalling contact (EF000422) | No |
| Signalling at the device (EF004241) | Optic |
| Category type 2 (EF004230) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |