View larger
1SBH137001R1331
137001
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC159655_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101027M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 77 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.27 kg |
| Technical | |
| Number of Auxiliary Contacts NO | 3 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 14-13 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Control Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (400 / 440 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 1 A / 72 W | |
| (110 V) 0.55 A / 60 W | |
| (125 V) 0.55 A / 69 W | |
| (220 V) 0.27 A / 60 W | |
| (250 V) 0.27 A / 68 W | |
| (400 V) 0.15 A / 60 W | |
| (500 V) 0.13 A / 65 W | |
| (600 V) 0.1 A / 60 W | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
| (DC-13) 900 cycles per hour | |
| Maximum Mechanical Switching Frequency | 6000 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V |
| 60 Hz 100 ... 250 V | |
| DC Operation 100 ... 250 V | |
| Power Loss | at 6 A per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Between Coil De-energization and NO Contact Opening 11 ... 95 ms | |
| Between Coil Energization and NC Contact Opening 38 ... 90 ms | |
| Between Coil Energization and NO Contact Closing 40 ... 95 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Auxiliary Circuit 10 mm |
| Control Circuit 10 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Control Circuit 1.2 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor Relay |
| Technical UL/CSA | |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb |
| Control Circuit 11 in·lb | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 g |
| Open, Shock Direction: B1 5 g | |
| Shock Direction: A 30 g | |
| Shock Direction: B2 15 g | |
| Shock Direction: C1 25 g | |
| Shock Direction: C2 25 g | |
| Resistance to Vibrations | 4g Closed Position & 2g Open position 5 ... 300 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | a000906b-ee90-4914-a705-5dbe89ad884e China |
| Simplified SCIP | 08ed39a6-d5f0-4b77-9a7c-3ad1a5fdfce0 France |
| 50dfbd34-ce1f-4ba9-a9c8-8ea154f200e0 Sweden | |
| e32fc31c-ba09-4e2d-b9c0-5153dee29d4b Croatia | |
| dd5d464d-48d7-4e22-a751-c9cb6a7c51e5 Czech Republic | |
| 05c537b2-74e1-4315-b1bd-cc3488f94469 Germany | |
| 6d615b49-4560-4f9c-8a62-a6ca6cbaa101 Denmark | |
| fcf6a977-ffc4-4a13-aa36-46647fc45834 Bulgaria | |
| 0371d898-49b5-4aa0-8544-7cf410e6f415 Belgium | |
| 7f7fe1d5-690b-420b-816c-af5ad74f49e7 Greece | |
| 06b23ae7-55ec-4400-9b4e-243a62d05505 Spain | |
| d2055ce8-9d59-4388-b13a-6557cc1c8e49 Portugal | |
| b79060f8-ef03-45d7-a748-e435c580b744 Belgium | |
| 3b4eb8fa-4169-4455-8d03-e5d0ed0176d5 Finland | |
| 6a9db7a1-8d74-4bdf-b9a1-706b76f087f3 Hungary | |
| ef3b0b48-babb-42be-bd15-06d832124a2d Estonia | |
| c1bdd10d-447a-498f-90b0-b4219b53fcc8 Hungary | |
| c45981e2-78a5-4d77-b673-a0235182729b Netherlands | |
| c40d1270-6aae-4508-ae94-58d2f0e5153d Poland | |
| 169c4d16-87fc-495a-a480-a72d9b0c074f Norway | |
| a9936961-d1d2-49da-8833-c4767539bff9 Poland | |
| b4208a2c-0fdb-49ba-8b79-48f8d32ae739 Germany | |
| 8c80b00d-c7f3-4088-b4ed-a8db0b3d4b35 France | |
| ed5b84ba-c80a-4150-9f47-6b798bf3e6d4 Sweden | |
| 6ec38270-a4eb-49e5-a8b2-c40a8b55b0cf Germany | |
| f711759d-136f-4625-8b4a-5528cd99b329 Germany | |
| ebabf4ac-94de-4cc7-a6fe-b8d814487367 Germany | |
| 970cf98c-b19a-4e5b-9dba-765b1c7b9f36 Poland | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 1SBC101080M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E3000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 92.7 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108469A4900 |
| 9AKK108469A4902 | |
| ABS Certificate | ABS_20-2060694-PDA |
| BV Certificate | BV_2634H24899C1 |
| CB Certificate | CB_SE-116792 |
| CCC Certificate | CCC_2024010303656666 |
| Declaration of Conformity - CCC | CQC2011010303465426 |
| Declaration of Conformity - CE | 1SBD250005U1000 |
| Declaration of Conformity - UKCA | 1SBD250036U1000 |
| DNV Certificate | DNV_TAE00001BV-5 |
| EAC Certificate | EAC_RU C-FR ME77 B03544 |
| GOST Certificate | GOST_POCCFR.ME77.B06804.pdf |
| KC Certificate | KC-HW02016-21031A |
| LR Certificate | LRS_LR2003684TA-02 |
| RINA Certificate | RINA_ELE142224XG |
| RMRS Certificate | RMRS_1802702280 |
| UL Certificate | UL_20180227_E252354_2_1 |
| UL Listing Card | UL_E252354 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 87 mm |
| Package Level 1 Depth / Length | 79 mm |
| Package Level 1 Height | 47 mm |
| Package Level 1 Gross Weight | 0.27 kg |
| Package Level 1 EAN | 3471523100237 |
| Package Level 2 Units | box 27 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 315 mm |
| Package Level 2 Gross Weight | 14.58 kg |
| External Classifications and Standards | |
| Object Classification Code | K |
| ETIM 7 | EC000196 - Contactor relay |
| ETIM 8 | EC000196 - Contactor relay |
| ETIM 9 | EC000196 - Contactor relay |
| eClass | V11.0 : 27371001 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |
| E-Number (Finland) | 3706408 |
| E-Number (Sweden) | 3211452 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 100 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 100 V |
| Rated control supply voltage DC (EF003980) | 100 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Rated operation current Ie, 400 V (EF001378) | 3 A |
| Connection type auxiliary circuit (EF006820) | Screw connection |
| Mounting method (EF000003) | DIN-rail/screw |
| Interface (EF000594) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 1 |
| Number of auxiliary contacts as normally open contact (EF001376) | 3 |
| Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) | 0 |
| Number of auxiliary contacts as normally open contact, leading (EF007282) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With LED indication (EF005950) | No |
| Suitable for manual operation (EF002978) | No |