View larger
1SBH137001R1422
137001
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC159655_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101027M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 77 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.31 kg |
| Technical | |
| Number of Auxiliary Contacts NO | 2 |
| Number of Auxiliary Contacts NC | 2 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 14-13 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Control Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (400 / 440 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 1 A / 72 W | |
| (110 V) 0.55 A / 60 W | |
| (125 V) 0.55 A / 69 W | |
| (220 V) 0.27 A / 60 W | |
| (250 V) 0.27 A / 68 W | |
| (400 V) 0.15 A / 60 W | |
| (500 V) 0.13 A / 65 W | |
| (600 V) 0.1 A / 60 W | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour |
| (DC-13) 900 cycles per hour | |
| Maximum Mechanical Switching Frequency | 6000 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 250 ... 500 V |
| 60 Hz 250 ... 500 V | |
| DC Operation 250 ... 500 V | |
| Power Loss | at 6 A per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Between Coil De-energization and NO Contact Opening 11 ... 95 ms | |
| Between Coil Energization and NC Contact Opening 38 ... 90 ms | |
| Between Coil Energization and NO Contact Closing 40 ... 95 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Auxiliary Circuit 10 mm |
| Control Circuit 10 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Control Circuit 1.2 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor Relay |
| Technical UL/CSA | |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb |
| Control Circuit 11 in·lb | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 g |
| Open, Shock Direction: B1 5 g | |
| Shock Direction: A 30 g | |
| Shock Direction: B2 15 g | |
| Shock Direction: C1 25 g | |
| Shock Direction: C2 25 g | |
| Resistance to Vibrations | 4g Closed Position & 2g Open position 5 ... 300 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 501299e1-3f1f-47bb-bbc2-8620cf7e24dc China |
| Simplified SCIP | 64ec9214-8d09-4915-9a2e-2599ddf9469c Czech Republic |
| 3c18f97e-d4a4-40f0-b5b8-39181e21aab9 Norway | |
| e6df8623-3c6f-43a7-8726-cd8a54dbfedd Poland | |
| 3455306c-f556-4b93-994b-40c4efb44086 Belgium | |
| 74f45d66-b2be-492f-94a3-4169038dcb36 Finland | |
| b326d75a-d39a-446c-8004-ccc4a614b5a5 Germany | |
| aa54311b-a3f7-41f9-a789-2146581c1505 Spain | |
| bc7e9413-f679-442f-962c-f843ea484cd7 Germany | |
| 62c70d61-bd62-4c1d-a3f5-9dc427e3269f Germany | |
| 498f32ff-8e5e-4713-bd3f-628fc0f939f1 Denmark | |
| 19b4bc92-d05d-492c-a6fd-fff50a036432 Croatia | |
| fa1329ce-eae4-44b6-aebd-77ac06471db3 Greece | |
| 60bcd356-aac2-47a8-8aa7-166047c4f5b9 Estonia | |
| 1b282a37-2f76-475d-b211-045abd5a2904 Hungary | |
| 0659418e-c709-4fb6-824e-0410d41bc05d Netherlands | |
| 6e3a9307-3c95-4b0b-9064-3cccb3850404 Poland | |
| 53542047-cd54-4eb1-aacb-504a826f20d8 France | |
| c2c319c5-185a-456d-acec-a5da81307eae Hungary | |
| 2a04c4df-d5d7-4f4b-b7c3-883fb3fe0cb8 Belgium | |
| 34e08d39-aa3f-413a-8fe8-6c5ad480b35e Sweden | |
| 30790aa4-91d7-4d62-bca7-bc031fd4686f Germany | |
| 6f8a99c8-2f97-4c0c-af0a-16384fb15d3a Portugal | |
| 872ce996-0a86-4d70-80b9-03539280d178 Bulgaria | |
| 85e0263f-adbb-482c-91f0-014a231a46e1 Poland | |
| d7aaae42-04f2-49c5-908b-41f4053fc59f Sweden | |
| 9aa83c53-b3ba-4336-abdc-8877797b75e1 France | |
| f9edfad2-9bf2-457a-9dda-2ee39251fb50 Germany | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SBC101080M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E3000 |
| 2TFP200035A1001 | |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 86 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 28 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108469A4900 |
| 9AKK108469A4902 | |
| ABS Certificate | ABS_20-2060694-PDA |
| BV Certificate | BV_2634H24899C0 |
| CB Certificate | CB_SE-116792 |
| CCC Certificate | CCC_2024010303656666 |
| Declaration of Conformity - CCC | CQC2011010303465426 |
| Declaration of Conformity - CE | 1SBD250005U1000 |
| Declaration of Conformity - UKCA | 1SBD250036U1000 |
| DNV Certificate | DNV_TAE00001BV-5 |
| EAC Certificate | EAC_RU C-FR ME77 B03544 |
| GOST Certificate | GOST_POCCFR.ME77.B06804.pdf |
| KC Certificate | KC-HW02016-21031A |
| LR Certificate | LRS_LR2003684TA-02 |
| RINA Certificate | RINA_ELE142224XG |
| RMRS Certificate | RMRS_1802702280 |
| UL Certificate | UL_20180227_E252354_2_1 |
| UL Listing Card | UL_E252354 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 87 mm |
| Package Level 1 Depth / Length | 79 mm |
| Package Level 1 Height | 47 mm |
| Package Level 1 Gross Weight | 0.31 kg |
| Package Level 1 EAN | 3471523100145 |
| Package Level 2 Units | box 27 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 315 mm |
| Package Level 2 Gross Weight | 16.74 kg |
| External Classifications and Standards | |
| Object Classification Code | K |
| ETIM 7 | EC000196 - Contactor relay |
| ETIM 8 | EC000196 - Contactor relay |
| ETIM 9 | EC000196 - Contactor relay |
| eClass | V11.0 : 27371001 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |
| E-Number (Finland) | 3706402 |
| E-Number (Sweden) | 3211449 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 250 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 250 V |
| Rated control supply voltage DC (EF003980) | 250 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Rated operation current Ie, 400 V (EF001378) | 3 A |
| Connection type auxiliary circuit (EF006820) | Screw connection |
| Mounting method (EF000003) | DIN-rail/screw |
| Interface (EF000594) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 2 |
| Number of auxiliary contacts as normally open contact (EF001376) | 2 |
| Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) | 0 |
| Number of auxiliary contacts as normally open contact, leading (EF007282) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With LED indication (EF005950) | No |
| Suitable for manual operation (EF002978) | No |