View larger
1SDA071342R1
071342
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 4ba6bc33-d9d5-49d1-8b8b-ed09636e3675 China |
| Simplified SCIP | 641ca43e-4d24-4321-9be2-85384da99ac8 Belgium |
| ad5d254a-b02c-466c-ae5f-94fbd69d2f93 France | |
| 820099b1-cbbb-4848-8200-3d354cab1696 Germany | |
| 6f04096b-fecf-43af-9346-b5aa53968254 Finland | |
| 017664e4-db4a-4e70-9981-9e3b0be43f81 Denmark | |
| bc820df1-3d1c-4b6a-b6aa-15bd982a8c47 Croatia | |
| 2b665a23-dcfc-490f-a43c-7fea38778210 Belgium | |
| aeffd8de-aa20-45e0-b947-61ef3a1985d1 Hungary | |
| 24f88761-f1c2-403a-92fb-0a50408141be Germany | |
| 1f422ee0-fb15-47f2-8137-32f64a31b6e9 Greece | |
| 9430f8d2-aeb3-4084-89fc-08e212f84977 Sweden | |
| 0e3c26e8-4fa1-4530-96d8-651ebe60e02a France | |
| 9d6a37a8-37b5-4178-bfdd-5b0c87e6488e Germany | |
| c1d92da0-c22d-4bd0-bfe2-baaea10d79ab Spain | |
| 84201dc3-9b35-4189-b55f-21ad3792056d Portugal | |
| 7ebe5d97-e366-47e4-b541-90ec88ea9ca5 Norway | |
| 89de6f1b-27b0-4e66-b1c7-f1747939a1af Hungary | |
| b1e8266a-069f-45fd-abad-73d6b347561d Poland | |
| 48b44eb1-b203-4688-8426-fd6dc071297f Estonia | |
| 39000d16-b4aa-4266-96b5-629ba0a4b91d Poland | |
| e4db7222-757b-4281-a811-55aadd0e6dc0 Bulgaria | |
| efef134e-ef85-446f-9c8a-91a24fefda34 Sweden | |
| 450af4f7-c7bd-4761-b640-ed567819b1ff Germany | |
| 3743b332-03d1-4b7b-b53f-98edd67eae2c Czech Republic | |
| 2a93d538-c64c-4537-b3a6-77a5127f1f15 Poland | |
| c4ff0b8b-e27c-46ad-8c23-6c2ee93d31b5 Netherlands | |
| c6133b50-ebdc-4242-aba8-434ed43596dc Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACNEEBB000A000000XX |
| EAN | 8015644751920 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644751920 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 31 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |