View larger
1SVR360563R1001
360563
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| classification | |
|---|---|
| Minimum order quantity | 1 piece |
| Tariff code | 85044095 |
| Popular Downloads | |
| Technical data, technical information | 2CDC114099D0201 |
| Instructions and manuals | 1SVC360560M0000 |
| Dimensions | |
| Product Width | 40 mm |
| Product height | 129.4 mm |
| Product length | 136 mm |
| Product Weight | 0.74 kg |
| Packaging Information | |
| Packaging Level 1 Width | 70 mm |
| Level 1 Long Packaging | 168 mm |
| Packaging Level 1 High | 160 mm |
| Packaging Level 1 Weight | 0.87 kg |
| EAN Level 1 Packaging | 4013614503818 |
| Packaging Level 1 Units | Box 1 piece |
| Technique | |
| function | Switch mode power supply |
| Number of phases | 1-phase |
| Nominal input voltage (UIN) | 100 ... 240 V AC |
| 90 ... 300 V DC | |
| Input voltage (Uin) | 85 ... 264 V AC |
| 90 ... 300 V DC | |
| Typical Input Current | (115 V AC) 1.1 A |
| (230 V AC) 0.6 A | |
| Timeout | (230 V AC) min. 50 ms |
| Nominal Frequency (f) | 50 / 60 Hz |
| Nominal frequency limits | 45 ... 65 Hz |
| Output Features | U/I characteristic curve with power reserve |
| Output power rating | 120 W |
| Output power | 120 W |
| Nominal Output Voltage | 24 V DC |
| Output voltage (Uout) | 24 V DC |
| Rated Output Current | -25 °C ... +40 °C 7.5 A |
| -25 °C ... +60 °C 5 A | |
| Output current | 5 A |
| Maximum output current (Iout) | 7.5 A |
| Nominal impulse-supported voltage (Uimp) | Input Circuit / Output Circuit 4 kV |
| Input Circuit / PE 4 kV | |
| Input Circuit / Relay Contact 4 kV | |
| Output Circuit / PE 0.5 kV | |
| Output Circuit 0.5 kV | |
| Rated insulation voltage (Ui) | Input Circuit / Output Circuit 300 V |
| Input circuit / PE 300 V | |
| 300 V relay contact/input circuit | |
| Output circuit / PE 50 V | |
| Degree of protection | Housing IP20 |
| Terminals IP20 | |
| Degree of contamination | 2 |
| Input Circuit Connection Capability | Flexible with 0.5 ... 2.5 mm² |
| Flexible 0.5 ... 2.5 mm² | |
| Rigid 0.5 ... 4 mm² | |
| Connecting the Output Circuit Capacity | Flexible with 0.5 ... 2.5 mm² |
| Flexible 0.5 ... 2.5 mm² | |
| Rigid 0.5 ... 4 mm² | |
| Tightening torque | Auxiliary Circuit 0.5 N·m |
| Input Circuit 0.5 N·m | |
| Output Circuit 0.5 N·m | |
| Cable Stripping Length | Auxiliary circuit 8 mm |
| Input circuit 8 mm | |
| Output circuit 8 mm | |
| Recommended screwdriver | Input Circuit / Output Circuit PH1 |
| Input Circuit / Output Circuit 0.8 x 4 | |
| Minimum mounting distance | Electrical Conductive Board, Horizontal 25 mm |
| Electrical Conductive Board, Vertical 25 mm | |
| Other Device Same Type, Horizontal 25 mm | |
| Other Device Same Type, Vertical 25 mm | |
| Mounting position | Position 1 |
| 7 | |
| Mounting on contactors | TH35-15 (35 x 15 mm mounting rail) according to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm mounting rail) according to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.107.1 |
| IEC/EN 63000 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| IEC/EN 61204 | |
| UL 508 | |
| IEC/EN 61010-1 | |
| UL 61010-1 | |
| UL 61010-2-201 | |
| UL/CSA Technique | |
| Connection Capacity UL/CSA Input Circuit | Flexible with 20-12 AWG ferrule |
| Flexible 20-12 AWG | |
| Rigid 20-10 AWG | |
| Connection Capacity UL/CSA Output Circuit | Flexible 20-12 AWG |
| Rigid 20-10 AWG | |
| UL/CSA torque | Input Circuit 4.4 in·lb |
| Output Circuit 4.4 in·lb | |
| Electromagnetic Compatibility | |
| Electrostatic discharge (ESD immunity) according to IEC 61000-4-2 | Level 4 Air Discharge 15 kV |
| Level 4 Contact Discharge 8 kV | |
| Immunity to radiated electromagnetic field according to IEC 61000-4-3 | Level 3 10 V/m |
| Fast electrical transients (burst immunity) according to IEC 61000-4-4 | Level 4 Power Supply Port Signal 4 kV |
| Surge immunity according to IEC 61000-4-5 | Level 4 Line-to-Ground 4 kV |
| Level 4 Line-to-Line 2 kV | |
| Conducted disturbances Immunity according to IEC 61000-4-6 | Level 3 10 V |
| Electromagnetic Compatibility (EMC) | Immunity - Class B |
| Emission - Class B | |
| Environment | |
| Ambient Temperature | Operating -25 to +70 °C |
| Storage -40 ... +85 °C | |
| Maximum permissible operating altitude | 5000 m |
| Resistance to humid heat according to IEC 60068-2-30 | Test Db: 55°C, 2 cycles |
| Shock resistance according to IEC 60068-2-27 | 30g 3 shock absorbers 6 ms |
| Vibration resistance according to IEC 60068-2-6 | ±0.15 mm 10 ... 58 Hz |
| 10 sweep cycles on each axis: 2g 58 ... 150 Hz | |
| Material Compliance | |
| Conflict Minerals Notification Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD982001-4501 |
| RoHS Information | 1SVD982001-4401 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 22 July 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006535 |
| WEEE B2C / B2B | From company to company |
| WEEE Category | 5. Small equipment (no external dimension more than 50cm) |
| Certificates and Declarations (Document Number) | |
| ABS Certified | ABS_17-HG1591548-2-PDA |
| CB Certificate | CB_DK_103485_UL |
| cULus Certified | cULus508_20151021-E174460 |
| cURus Certificate | cURus60950_E196145-A10-UL |
| cURusANSI-12-12_20160629_E317914 | |
| Declaration of Conformity - CE | 1SVD982010-00 |
| Declaration of Conformity - UKCA | 1SVD982010-10 |
| DNV GL Certificate | DNV_GL_TAA00000YB_1 |
| EAC Certificate | EAC_RU_C-DE. ME77. B.02550 |
| SEMI Certificate | SEMI_F47_4787851718 |
| External Classifications and Standards | |
| Object Classification Code | T |
| ETIM 9 | EC002540 - DC-power supply |
| ETIM 10 | EC002540 - DC-power supply |
| E-class | V11.0 : 27040701 |
| UNSPSC | 39121004 |
| E Number (Finland) | 2712518 |
| E Number (Norway) | 6609457 |
| E Number (Sweden) | 5213179 |