View larger
1SFL431022R8400
431022
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 5309660-60 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 123.5 mm |
| Product Net Height | 148 mm |
| Product Net Weight | 1.8 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A |
| Rated Operational Power AC-3 (Pe) | (380 / 400 V) 45 kW |
| Rated Operational Power AC-6b (Pe) | (230 / 240 V) 40 °C, 50 / 60 Hz 35 kvar |
| (230 / 240 V) 55 °C, 50 / 60 Hz 35 kvar | |
| (230 / 240 V) 70 °C, 50 / 60 Hz 30 kvar | |
| (400 / 415 V) 40 °C, 50 / 60 Hz 65 kvar | |
| (400 / 415 V) 70 °C, 50 / 60 Hz 55 kvar | |
| (400 / 415 V) 55 °C, 50 / 60 Hz 65 kvar | |
| (440 V) 40 °C, 50 / 60 Hz 65 kvar | |
| (440 V) 55 °C, 50 / 60 Hz 65 kvar | |
| (440 V) 70 °C, 50 / 60 Hz 55 kvar | |
| (500 / 550 V), 40 °C, 50 / 60 Hz 70 kvar | |
| (500 / 550 V) 55 °C, 50 / 60 Hz 70 kvar | |
| (500 / 550 V) 70 °C, 50 / 60 Hz 60 kvar | |
| (690 V) 40 °C, 50 / 60 Hz 80 kvar | |
| (690 V) 55 °C, 50 / 60 Hz 80 kvar | |
| (690 V) 70 °C, 50 / 60 Hz 70 kvar | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | 240 cycles per hour |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 110 V |
| 60 Hz 110 ... 120 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 7.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 15 ms |
| Between Coil Energization and NO Contact Closing 10 ... 25 ms | |
| Connecting Capacity Main Circuit | Bar 30 mm² |
| Flexible with Cable End 1 x 10 ... 70 mm² | |
| Rigid 1 x 10 ... 95 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 1x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 30 mm² |
| Flexible with Cable End 2 x 6 ... 35 mm² | |
| Rigid 1 x 10 ... 95 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles | M8 hexagon socket screw with single connector |
| Tightening Torque | Main Circuit 8 N·m |
| Terminal Type | Cable Clamp |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 10 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g | |
| Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CB Certificate | CB_CN64637 |
| CQC Certificate | CQC2003010304088242 |
| CQC2009010304353513 | |
| Declaration of Conformity - CCC | 2020980304001551 |
| 2020980304001055 | |
| Declaration of Conformity - CE | 9AKK108471A1807 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 130 mm |
| Package Level 1 Depth / Length | 265 mm |
| Package Level 1 Height | 162 mm |
| Package Level 1 Gross Weight | 2 kg |
| Package Level 1 EAN | 7320500144619 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001079 - Capacitor contactor |
| ETIM 8 | EC001079 - Capacitor contactor |
| ETIM 9 | EC001079 - Capacitor contactor |
| eClass | V11.0 : 27371006 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4756 >> Capacitor magnet contactor |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 110 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 110 V |
| Voltage type for actuating (EF008242) | AC |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Type of electrical connection of main circuit (EF006819) | Other |
| Number of normally open contacts as main contact (EF001374) | 3 |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Rated reactive power at 400 V, 50 Hz (EF007044) | 65 kvar |