View larger
1SDA100205R1
1SDA100205R1
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Statement | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Order | |
| Ean | 8056221002592 |
| Minimum order quantity | 1 piece(s) |
| Customs tariff code | 85362090 |
| dimensions | |
| Product width | 105 mm |
| Product height | 160 mm |
| Product depth | 82.5 mm |
| Product Net Weight | 2.5 kg |
| Packaging information | |
| Packaging Unit Level 1 | Box 1 piece(s) |
| Packaging width level 1 | 145 mm |
| Packaging height level 1 | 210 mm |
| Packaging depth level 1 | 168 mm |
| Gross Packaging Weight Level 1 | 2.5 kg |
| EAN packaging level 1 | 8056221002592 |
| Additional information | |
| Type of switch to pair | Power Distribution |
| Main Product Type | SACE Tmax XT |
| Product name | Moulded Case Circuit Breaker |
| Product type | Automatic Circuit Breaker |
| version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Technical data | |
| Current Type | Ac |
| Electrical life | 120 cycles per hour |
| 8000 cycle(s) | |
| Mechanical durability | 240 cycles per hour |
| 25000 cycle(s) | |
| Number of poles | 3P |
| Opening duration | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Power loss | a Nominal Operating Conditions per Pole 16.40 W |
| Rated current (IN) | 250 A |
| Rated Frequency (f) | 50/60 Hz |
| Impulse sealing voltage (UImp) | 8 kV |
| Rated insulation voltage (Uthe) | 1000 V AC |
| Rated operating voltage | 690 V AC |
| Rated service short-circuit power (ICs) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Nominal extreme short circuit power (ICu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Uninterrupted current rating (Iu) | 250 A |
| Rated voltage (UR) | 690 V AC |
| Uncoupling | Ekip Dip LSI |
| Release type | EL |
| Short-circuit performance level | S |
| Reference standards | Iec |
| Subtype | XT4 |
| UL/CSA Technical Department | |
| Interrupting Rating acc. to UL489 | (240 V AC) 150 A |
| (480 V AC) 65 A | |
| (600 V AC) 25 A | |
| Certificates and declarations (document number) | |
| ATEX certified | No certification needed |
| Sheet | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| VDE Certificate | No certification needed |
| Mechanical drawings | 1SDH000722R0100 |
| Wiring diagram | 1SDM000068R0001 |
| Instructions and manuals | 1SDH000722R0001 |
| 1SDH000721R0510 | |
| External classifications and standards | |
| ETIM 9 | EC001023 - Shunt release (for power circuit breaker) |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Item Classification Code | Q |
| WEEE Category | 5. Small equipment (no external size greater than 50cm) |