View larger
1SDA068483R1
068483
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | a3743684-63f9-4034-9943-06f9fc1d8fa1 Italy (IT) |
| Simplified SCIP | 713010c1-05f0-4f18-99c9-e2424afefdc7 Sweden (SE) |
| adb67f37-1a5d-4ff6-8f5b-012060ae7c2a Denmark (DK) | |
| 471b94b8-6603-481c-b15e-c4758d33d5b8 Germany (DE) | |
| f9ef2f3f-0dee-493b-b924-83ea61a57730 Croatia (HR) | |
| 891d2b5d-7b38-49db-9cf5-7b08e9b2fe4d Germany (DE) | |
| e03c60ee-ef0a-4adc-9ee2-438e09308a3e Czech Republic (CZ) | |
| ae6849f9-c1ed-4cd5-83c4-eff24e4943cb Germany (DE) | |
| d1da0609-0472-462e-852d-c1a16fc18f15 France (FR) | |
| 00ef3c03-8be9-4d1d-a6e6-f71b06689820 Hungary (HU) | |
| c6a23d0c-954f-405b-addd-dea3c4e91302 Spain (ES) | |
| 773228ae-a10a-4bbe-9ad8-d7fccd00b731 Belgium (BE) | |
| a40d65e2-335a-4920-89e8-7abe24e31a0b Germany (DE) | |
| 3e0ea0cd-c859-4c48-a0d9-2ad010f18eab Poland (PL) | |
| 3fea2922-f4a4-4881-8b6d-0449ffa50901 Poland (PL) | |
| 4c2a02e6-fa23-46b2-a5bd-f94438bfb1f4 Finland (FI) | |
| bbf604d1-e2dd-406e-9899-e0b6d845368a Poland (PL) | |
| c005c13e-0940-4032-8d07-2bcf96ab0c48 Hungary (HU) | |
| bd99d451-9012-4572-a48d-757baeef1583 Sweden (SE) | |
| 61bcb02b-6570-41f2-9306-583b6b26b224 Netherlands (NL) | |
| 97ed7319-1853-4262-8e4a-5e47b5bdc5c3 Norway (NO) | |
| 95afd1fb-de3e-4726-a964-172f94c07dbd Bulgaria (BG) | |
| bbd6029c-e980-409b-8882-7b06f665c54c Belgium (BE) | |
| 57a693cb-16d8-4854-bd5a-4a63a77364db Estonia (EE) | |
| 48fb8a1d-a854-4b10-bfef-2a0fe6a3c242 Greece (GR) | |
| b66f55d6-395d-457c-b802-b81f6ced0044 France (FR) | |
| 29a1026a-8707-41ab-84e0-ef339ed119cb Germany (DE) | |
| 594b29bc-7dde-43c9-959c-e1c80e7bed7e Portugal (PT) | |
| Ordering | |
| Order Code US and Canada | XT4SE3100FFF000XXX |
| EAN | 8015644023898 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 145 mm |
| Package Level 1 Height | 210 mm |
| Package Level 1 Depth / Length | 168 mm |
| Package Level 1 Gross Weight | 2.5 kg |
| Package Level 1 EAN | 8015644023898 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 4.20 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 100 A |
| Rated Frequency (f) | 50/60 Hz |
| Rated Voltage (Ur) | 690 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V AC |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 36 kA | |
| (525 V AC) 25 kA | |
| (690 V AC) 12 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH002230A1003 |
| Technical UL/CSA | |
| Interrupting Rating acc. to UL489 | (240 V AC) 150 A |
| (480 V AC) 65 A | |
| (600 V AC) 25 A | |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| 1SDH000721R0506 | |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 100 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 100 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 100 A |
| Adjustment range undelayed short-circuit release (EF007131) | 100 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |