View larger
1SDA068256R1
068256
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2350 |
| Environmental Product Declaration - EPD | 9AKK108468A2294 |
| 9AKK108468A7794 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 56.6 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | fa430eb2-4800-4ae3-a52a-f8375ee43a6b Italy |
| Simplified SCIP | f89b9113-764b-4df5-a909-032c1936886d Germany |
| 5ef83636-f141-45df-a379-6ccae5fef1a5 Poland | |
| 466b15da-ae2f-4796-8514-0b06e0f308d8 Netherlands | |
| 05260b5e-0bf5-4709-9e92-daa541f24a8b Netherlands | |
| 57211169-9dda-42ef-9c1e-648e4d4c9364 Estonia | |
| 52b999cb-51cc-4426-aa4a-61aa641063f8 France | |
| 00bc3c46-8e54-4ba9-9f4f-4a1e4ed33e9b Netherlands | |
| 1b7dc436-6c45-4089-a2e6-698ff519868c Spain | |
| aa0ef85f-3a7d-4bd6-99ed-07626249c604 Netherlands | |
| 4186a56c-9827-4c4b-8c9f-8876e30a599e Poland | |
| 7a0ae096-66d6-482b-87b1-c1accf2d8324 Norway | |
| 9e91fcd6-997d-4be4-82ab-23f198ef08eb Finland | |
| 5a1bb451-c847-4ec1-af46-4b6e94dc4a09 Netherlands | |
| 3c313456-4c84-4d6d-8926-fcc336a22089 Germany | |
| 238cde21-88c5-4b8a-82c3-a1d107cdeab4 Denmark | |
| 28a4a2ed-8b10-4d18-8faf-95403523ab8f Germany | |
| 5d22a525-1061-4fa1-b0a2-537698e87865 Croatia | |
| 6810c176-7994-4674-9ecd-ab28b0147615 Czech Republic | |
| 51d9a2a0-0ff6-4d3e-bb41-2e2bc6b43150 Poland | |
| 744c352c-5d8a-472e-a110-93883970e302 France | |
| 2cdc8b6e-211f-4d0d-8dea-638842ae0664 Sweden | |
| 4601700d-1435-4664-a572-97f3c1c7954a Germany | |
| cb8e5651-ce8d-4712-9af9-6452fbeaa663 Germany | |
| 75d66b08-1610-43aa-9e26-bdfd1ae3ffee Greece | |
| a45befae-7bbb-4979-aae7-b9ba3721b5f9 Portugal | |
| 4835c037-75c0-46dc-8de0-56d140a050af Bulgaria | |
| 2a26c249-a1e4-44ee-bba3-8237f725fd90 Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT3NE3200NFF000XXX |
| E-Number (Norway) | 4379794 |
| EAN | 8015644021627 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 105 mm |
| Product Net Height | 150 mm |
| Product Net Depth / Length | 70 mm |
| Product Net Weight | 1.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 155 mm |
| Package Level 1 Height | 190 mm |
| Package Level 1 Depth / Length | 155 mm |
| Package Level 1 Gross Weight | 1.7 kg |
| Package Level 1 EAN | 8015644021627 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Generator Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0409 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 85..192 mm² |
| Current Type | AC/DC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 3P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 13.2 W |
| Rated Current (In) | 200 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 600 A |
| Rated Insulation Voltage (Ui) | 800 V |
| Rated Operational Voltage | 690 V AC |
| 500 V DC | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 18 kA | |
| (500 V AC) 15 kA | |
| (525 V AC) 9,75 kA | |
| (690 V AC) 3,75 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 2 Poles in Series 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (240 V AC) 50 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 20 kA | |
| (525 V AC) 13 kA | |
| (690 V AC) 5 kA | |
| (250 V DC) 2 Poles in Series 36 kA | |
| (500 V DC) 3 Poles in Series 50 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M8 |
| Release | TMG |
| Release Type | TM |
| Setting Range | 140...200 A |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT3 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5530 |
| GL Certificate | 1SDL000163R0094 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000720R0100 |
| Mechanical Drawings | 1SDH000720R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000720R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |