View larger
1SDA068156R1
068156
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2352 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | b226ed93-8a91-49ec-9e43-1a2d4e6c6f33 Italy (IT) |
| Simplified SCIP | 41473edd-a81e-4472-8900-c535d91d3700 Netherlands (NL) |
| 75024810-572c-40da-b89b-2e979a4958a7 Hungary (HU) | |
| 7207faa6-6191-4b37-8702-e576ff87be6d Poland (PL) | |
| 8593cfde-756e-41ec-98ae-5d38ab3e26a6 Estonia (EE) | |
| 479a3784-da14-416d-a530-f8b6b5b110b0 Hungary (HU) | |
| a57bf18e-9f70-4e9a-b3de-ea087f0e09d0 Spain (ES) | |
| 31070b3b-1085-4c7c-bce5-579f1e297854 Belgium (BE) | |
| 71b35828-df91-4b5d-8f54-eb677a3b8a46 Czech Republic (CZ) | |
| 75fb7705-9042-4edf-b3fd-b14727d8a6ee Germany (DE) | |
| 7ba7cfe6-00f9-4ab1-85b6-15da98e369ee France (FR) | |
| dffe95c8-220f-41e7-8085-a90d95e4d596 Germany (DE) | |
| a4edc024-bf9d-491a-9171-114c8a241a22 Croatia (HR) | |
| daba93b8-4a15-4006-85f3-655ed96a5313 Sweden (SE) | |
| 963c84ff-6000-4d85-843e-f288ea0215ae Denmark (DK) | |
| 62711e7d-df62-48e9-9d88-660027b1dbf2 Germany (DE) | |
| 14b406a9-e9ec-4955-9590-9241c687a49d Germany (DE) | |
| 964e0789-3a18-416c-9637-9716494b0061 Finland (FI) | |
| da4a422c-8e37-4859-9a9d-3dd01cf907f1 Poland (PL) | |
| 24bf2da1-1e90-41be-bfdc-b22d505c7cd1 Norway (NO) | |
| eddd4b44-700d-4fc8-b3e5-1fc07a329bed Belgium (BE) | |
| dc48a103-418a-44a4-8faf-ec8f2cb5f331 Greece (GR) | |
| f40130d6-7265-4518-b5b7-3ff8e1a31f31 Poland (PL) | |
| 9f4c173d-2654-4af7-80cb-13f8a9833008 Bulgaria (BG) | |
| 80a2a9de-ffa5-4b10-bfb7-0d63097c82b1 Sweden (SE) | |
| 4775e326-5654-44ff-bfaa-2820f818d24e Portugal (PT) | |
| 04b4f69e-7574-41bd-be4e-e847189ec361 Germany (DE) | |
| dc771ef4-c6a5-48d0-99a3-ee422f26ab41 France (FR) | |
| Ordering | |
| Order Code US and Canada | XT4NE4160FFF000XXX |
| EAN | 8015644020538 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 3.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 145 mm |
| Package Level 1 Height | 210 mm |
| Package Level 1 Depth / Length | 168 mm |
| Package Level 1 Gross Weight | 3.5 kg |
| Package Level 1 EAN | 8015644020538 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4 |
| Opening Time | CB with SOR 15 ms |
| CB with UVR 15 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 8.90 W |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50/60 Hz |
| Rated Voltage (Ur) | 690 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V AC |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0677 |
| Technical UL/CSA | |
| Interrupting Rating acc. to UL489 | (240 V AC) 100 A |
| (480 V AC) 35 A | |
| (600 V AC) 22 A | |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | 2CDC210017C0101 |
| 1SDC210100D0206 | |
| 1SXF210033C2001 | |
| 1SDC210099D0206 | |
| 1SXF210034C2001 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| 1SDH000721R0506 | |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |