XT4N160 Ekip LSI R160 4P F F XT4N 160 Ekip LSI In=160A 4p F F

Automation > Power circuit-breaker for trafo/generator/installation protection
Molded Case Circuit Breakers ≤ 250 A Xtmax

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ABB EcoSolutions
ABB EcoSolutionsYes
Circular Value
Circular Design Principles Recyclability RateDesign for Closing Resource Loops - Standard EN45555 - 56.30 %
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
End of Life Instructions9AKK108468A2352
Group Waste to Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA9AKK108467A8326
Eco Transparency
Environmental Product Declaration - EPD9AKK108469A1858
9AKK108468A1898
Environmental
Environmental Information9AKK108467A6707
REACH Declaration9AKK108466A1425
RoHS Information9AKK108466A1424
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPb226ed93-8a91-49ec-9e43-1a2d4e6c6f33 Italy (IT)
Simplified SCIP41473edd-a81e-4472-8900-c535d91d3700 Netherlands (NL)
75024810-572c-40da-b89b-2e979a4958a7 Hungary (HU)
7207faa6-6191-4b37-8702-e576ff87be6d Poland (PL)
8593cfde-756e-41ec-98ae-5d38ab3e26a6 Estonia (EE)
479a3784-da14-416d-a530-f8b6b5b110b0 Hungary (HU)
a57bf18e-9f70-4e9a-b3de-ea087f0e09d0 Spain (ES)
31070b3b-1085-4c7c-bce5-579f1e297854 Belgium (BE)
71b35828-df91-4b5d-8f54-eb677a3b8a46 Czech Republic (CZ)
75fb7705-9042-4edf-b3fd-b14727d8a6ee Germany (DE)
7ba7cfe6-00f9-4ab1-85b6-15da98e369ee France (FR)
dffe95c8-220f-41e7-8085-a90d95e4d596 Germany (DE)
a4edc024-bf9d-491a-9171-114c8a241a22 Croatia (HR)
daba93b8-4a15-4006-85f3-655ed96a5313 Sweden (SE)
963c84ff-6000-4d85-843e-f288ea0215ae Denmark (DK)
62711e7d-df62-48e9-9d88-660027b1dbf2 Germany (DE)
14b406a9-e9ec-4955-9590-9241c687a49d Germany (DE)
964e0789-3a18-416c-9637-9716494b0061 Finland (FI)
da4a422c-8e37-4859-9a9d-3dd01cf907f1 Poland (PL)
24bf2da1-1e90-41be-bfdc-b22d505c7cd1 Norway (NO)
eddd4b44-700d-4fc8-b3e5-1fc07a329bed Belgium (BE)
dc48a103-418a-44a4-8faf-ec8f2cb5f331 Greece (GR)
f40130d6-7265-4518-b5b7-3ff8e1a31f31 Poland (PL)
9f4c173d-2654-4af7-80cb-13f8a9833008 Bulgaria (BG)
80a2a9de-ffa5-4b10-bfb7-0d63097c82b1 Sweden (SE)
4775e326-5654-44ff-bfaa-2820f818d24e Portugal (PT)
04b4f69e-7574-41bd-be4e-e847189ec361 Germany (DE)
dc771ef4-c6a5-48d0-99a3-ee422f26ab41 France (FR)
Ordering
Order Code US and CanadaXT4NE4160FFF000XXX
EAN8015644020538
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width140 mm
Product Net Height160 mm
Product Net Depth / Length82.5 mm
Product Net Weight3.5 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width145 mm
Package Level 1 Height210 mm
Package Level 1 Depth / Length168 mm
Package Level 1 Gross Weight3.5 kg
Package Level 1 EAN8015644020538
Additional Information
Circuit Breaker Type to be AssociatedPower Distribution
Connecting Capacity Main CircuitBusbar 85..200 mm²
Current TypeAC
Electrical Durability120 cycles per hour
8000 cycle
Mechanical Durability240 cycles per hour
25000 cycle
Number of Poles4
Opening TimeCB with SOR 15 ms
CB with UVR 15 ms
Order Multiple1 piece
Power Lossat Rated Operating Conditions per Pole 8.90 W
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
Rated Current (In)160 A
Rated Frequency (f)50/60 Hz
Rated Voltage (Ur)690 V AC
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Insulation Voltage (Ui)1000 V AC
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
Rated Uninterrupted Current (Iu)160 A
Recommended Screw DriverMain Circuit M8
ReleaseEkip LSI
Release TypeEL
Short-Circuit Performance LevelN
StandardsIEC60947-2
Sub-typeXT4
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque8 N·m
VersionF
CAD Dimensional Drawing1SDH001295R0677
Technical UL/CSA
Interrupting Rating acc. to UL489(240 V AC) 100 A
(480 V AC) 35 A
(600 V AC) 22 A
Certificates and Declarations
ATEX CertificateNo certification needed
Data Sheet, Technical Information2CDC210017C0101
1SDC210100D0206
1SXF210033C2001
1SDC210099D0206
1SXF210034C2001
Declaration of Conformity - CE9AKK106713A5529
GL Certificate1SDL000163R0095
LR Certificate1SDL000163R0100
UL CertificateNo certification needed
VDE CertificateNo certification needed
Dimension Diagram1SDH000722R0100
Mechanical Drawings1SDH000722R0100
Wiring Diagram1SDM000068R0001
Instructions and Manuals1SDH000722R0001
1SDH000721R0506
Classifications
ETIM 7EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
UNSPSC39120000
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.