View larger
1SDA068146R1
068146
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2352 |
| Environmental Product Declaration - EPD | 9AKK108469A1858 |
| 9AKK108468A1898 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 56.30 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 437c49a1-547a-4aad-ae10-321d19bad45f Italy |
| Simplified SCIP | 788a101e-d9ac-4aee-9633-e5c69d5a6704 Germany |
| 420041cf-200f-4090-abb1-06b6555e979e Hungary | |
| 7bd83ed2-c54d-4d54-8539-4562036d1139 Sweden | |
| 4beb861e-61df-475f-8857-65fd244d5595 Sweden | |
| 8c0c7a80-671d-4cf2-8c43-f11b7a5b6629 Poland | |
| 0f78ca4e-d467-45ea-a04e-3b2fc7294a7a Belgium | |
| cc34f2ab-c781-4572-842b-c64c23196bb8 France | |
| 49928f76-9402-45ee-b2ba-605c4b2f2ea2 Germany | |
| b4f6f1c4-8964-45a4-aa5d-0c8bed1b2da2 Bulgaria | |
| 664f5313-bade-40a1-b952-274cfc7f14df Germany | |
| 076ceb7b-7f95-4c6d-aedc-503c7883056b Portugal | |
| a2fa783d-0c34-4d1c-8f54-377e7bc706c5 Belgium | |
| 31471705-aaa2-4d6d-a4a3-db35b753d61b Estonia | |
| b515a22f-87a3-4bff-b146-ca98d2b92a98 Greece | |
| 89528e02-3053-448e-9d24-b800aad6994c Poland | |
| d4384234-78bd-4f82-aa75-3b0f5d2bca7a Norway | |
| aea68068-d660-4970-86c6-80b127bbb021 Denmark | |
| d0119977-eef5-431d-8c0d-50e1faf28879 Finland | |
| 7a1ac323-3d04-4449-84f1-4ab5550ff842 Netherlands | |
| 02e2f49d-3c7e-4108-863d-e76ecb41532d Germany | |
| 4b15734d-7cea-490c-b8c0-4521799f90af Germany | |
| 58738a94-e33f-48e2-baae-48bdb0d751b5 Croatia | |
| d599f083-6071-4426-a8b2-2766a45e1389 Hungary | |
| cb325a1a-f633-4c43-946c-ee5f727ea7f6 Spain | |
| 3d113a02-59e5-43d3-9b68-44d9d015f60c Czech Republic | |
| ef527b56-089b-4eff-b332-222ed5794695 Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT4NE4160EFF000XXX |
| E-Number (Norway) | 4309767 |
| EAN | 8015644696054 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 140 mm |
| Product Net Height | 160 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 2.96 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 151 mm |
| Package Level 1 Height | 214 mm |
| Package Level 1 Depth / Length | 171 mm |
| Package Level 1 Gross Weight | 3.116 kg |
| Package Level 1 EAN | 8015644696054 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001295R0677 |
| Technical | |
| Connecting Capacity Main Circuit | Busbar 85..200 mm² |
| Current Type | AC |
| Electrical Durability | 120 cycles per hour |
| 8000 cycle | |
| Mechanical Durability | 240 cycles per hour |
| 25000 cycle | |
| Number of Poles | 4P |
| Opening Time | CB with SOR 30 ms |
| CB with UVR 30 ms | |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 8.9 W |
| Rated Current (In) | 160 A |
| Rated Frequency (f) | 50 / 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (240 V AC) 65 kA | |
| (380 V AC) 36 kA | |
| (415 V AC) 36 kA | |
| (440 V AC) 36 kA | |
| (500 V AC) 30 kA | |
| (525 V AC) 20 kA | |
| (690 V AC) 10 kA | |
| Rated Uninterrupted Current (Iu) | 160 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M8 |
| Release | Ekip Dip LS/I |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC60947-2 |
| Sub-type | XT4 |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 8 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| Data Sheet, Technical Information | SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK106713A5529 |
| GL Certificate | 1SDL000163R0095 |
| LR Certificate | 1SDL000163R0100 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Dimension Diagram | 1SDH000722R0100 |
| Mechanical Drawings | 1SDH000722R0100 |
| Wiring Diagram | 1SDM000068R0001 |
| Instructions and Manuals | 1SDH000722R0001 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |