ABB 1SBH901074R8040 1SBH901074R8040 ABB NX40E-80 220-230V50Hz 230-240V60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SBH901074R8040 ABB NX40E-80 220-230V50Hz 230-240V60Hz

1SBH901074R8040

901074

ABB

1 Pcs.

NX40E-80 220-230V50Hz 230-240V60Hz NX40E-80 220-230V50Hz/230-240V60Hz Contactor relay

Automation > Contactor relay
Contactors and overload relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC178845_EPLAN
Data Sheet, Technical Information1SBC100187L0203
Instructions and ManualsNo
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width44 mm
Product Net Depth / Length74 mm
Product Net Height74 mm
Product Net Weight0.315 kg
Technical
Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC0
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.30 A / 75 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening TorqueAuxiliary Circuit 1 N·m
Control Circuit 1 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Technical UL/CSA
Tightening Torque UL/CSAAuxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstandaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP00616fed-9ea5-4b62-a890-6199a254f2f1 Sweden
10fdee06-0b9f-4421-a9dc-1843bbce216d Sweden
22480de5-c312-43e6-a922-bfbe3f563417 Netherlands
33a68082-9b1f-46dc-9826-809609b98cbe Italy
425e30cd-8997-44d7-835d-4667fcbbe753 Hungary
5527f775-24c4-44d2-8871-e3026e8ac14f Croatia
56d82315-e263-4def-b1c5-dc75a8d57f88 Poland
5f5da01c-8cdb-4836-a647-64c639197c45 Belgium
628858bd-089d-49d7-93ca-4af1945d56e7 France
6d57a814-ba67-446f-a993-fc29c31cfb47 Finland
6f5963e2-7d28-4aa6-b283-d4986cbb79d0 Hungary
862b37f0-354e-4420-b80e-8b6f7dc20780 Germany
8ec37bd1-2ede-49b6-9738-befcff41ee71 Belgium
97a5e425-4d8e-4918-98d7-b047b28f9b21 Denmark
a0aff0ab-b469-46d3-b22d-7bc444a1385c Czech Republic
a290f7d1-e23e-468a-9804-dd483fe9d168 Spain
b4002da7-1b15-41f9-8a61-42ff924eb0ac France
cc346738-0011-4ae7-954a-30022681888c Greece
cd9b4a53-d1e5-4eed-aa0e-f5e57254cd85 Portugal
e243f09a-b451-435f-98c6-e5cd338a1c40 Estonia
ef62bdf8-6b04-4d5e-a2d6-296b4af01c47 Norway
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
CB Certificate9AKK107492A7071
CCC Certificate9AKK107492A7095
CQC CertificateCQC2013010304653298
Declaration of Conformity - CCC2020980304001057
Declaration of Conformity - CE1SBD250012U1000
UL Certificate9AKK108471A3992
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width48 mm
Package Level 1 Depth / Length78 mm
Package Level 1 Height79 mm
Package Level 1 Gross Weight0.315 kg
Package Level 1 EAN3471522390806
External Classifications and Standards
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121500
IDEA Granular Category Code (IGCC)4755 >> Contactors
E-Number (Finland)3707386

ETIM for 1SBH901074R8040 Low-voltage industrial controls and switchgear (EC000196)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 220 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie, 400 V (EF001378) 2 A
Connection type auxiliary circuit (EF006820) Screw connection
Mounting method (EF000003) Other
Interface (EF000594) No
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 4
Number of auxiliary contacts as normally closed contact, delayed switching (EF007281) 0
Number of auxiliary contacts as normally open contact, leading (EF007282) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With LED indication (EF005950) No
Suitable for manual operation (EF002978) No